[Comparison of single sample methods for determination of plasma clearance using 99mTc-MAG3]

Kaku Igaku. 1998 Oct;35(8):689-95.
[Article in Japanese]

Abstract

We compared relationship among three single blood sampling methods which have been proposed for determination of plasma clearance with 99mTc-MAG3. Russell's and Bubeck's algorithms were employed for 48 adults (average age: 53 years) and Bubeck's and Piepsz's algorithms were used in 9 children (average age: 5.8 years). Three methods showed very high correlation among them. However, Russell's and Piepsz's methods were about 1.4 times higher than Bubeck's method in calculating plasma clearance of 99mTc-MAG3. The present study indicates that three methods discussed here are useful for the determination of plasma clearance with 99mTc-MAG3. In addition, Bubeck's method may be preferable as a reference for single plasma sampling method because of common application to adults and children.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Algorithms
  • Child
  • Female
  • Humans
  • Kidney Diseases / diagnostic imaging*
  • Male
  • Middle Aged
  • Radioisotope Renography / methods*
  • Radiopharmaceuticals* / blood
  • Technetium Tc 99m Mertiatide* / blood

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Mertiatide