A randomized comparison of surfactant dosing via a dual-lumen endotracheal tube in respiratory distress syndrome. The Spanish Surfactant Collaborative Group

Pediatrics. 1998 Apr;101(4):E4. doi: 10.1542/peds.101.4.e4.

Abstract

Aim: To determine if 1-minute instillation of Curosurf via a dual-lumen endotracheal tube without interruption of mechanical ventilation could decrease the incidence of hypoxia (drop in oxygen saturation [SaO2] to <80%, or of transcutaneous partial pressure of oxygen [PtcO2] to <50 mm Hg [6.6 kPa]) and bradycardia (heart rate below 80 beats/minute) at dosing, without affecting the efficacy of the standard bolus delivery.

Design: Prospective, multicenter, randomized, nonblinded clinical trial.

Setting: Neonatal intensive care units of the Spanish Surfactant Collaborative Group.

Patients and methods: One hundred ninety-eight infants (birth weight 600-2000 g) with respiratory distress syndrome needing mechanical ventilation with a fraction of inspired oxygen [FIO2] 0.40 were randomized before 24 hours to receive 200 mg/kg of Curosurf, either by bolus instillation (n = 99) or by a simplified dosing technique (n = 99), giving the full dose in 1 minute via a dual-lumen endotracheal tube without positioning, interruption of mechanical ventilation, or bagging. Two additional doses (100 mg/kg) were given within 12 and 24 hours of first dose, by the same method, if the infant still needed mechanical ventilation and had a FIO2 0.30. The effects of both procedures on the incidence of acute adverse events at dosing, gas exchange, ventilator requirements, and outcome at 28 days were compared.

Results: Fewer episodes of hypoxia (18 vs 40% of doses), and a smaller decrease in heart rate and SaO2 were observed in the dual-lumen group. Efficacy of surfactant, based on improvement of oxygenation, ventilator requirements, and number of doses required, was similar in both groups. Infants in the dual-lumen group had a lower total time exposure to supplemental oxygen (195+/-199 vs 266+/-221 hours). No differences in the incidence of air leaks, intraventricular hemorrhage, patent ductus arteriosus, bronchopulmonary dysplasia, or survival were observed.

Conclusion: A simplified 1-minute Curosurf dosing procedure via a dual-lumen endotracheal tube without fractional doses, ventilator disconnection, changes in the infant's position, or manual bagging was found to reduce the number of dosing-related adverse transient episodes of hypoxia. Although the simplified method appeared to be as effective as bolus delivery, this should be confirmed in a larger trial.

Publication types

  • Clinical Trial
  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biological Products*
  • Bradycardia / prevention & control
  • Female
  • Humans
  • Hypoxia / prevention & control
  • Infant, Newborn
  • Infusions, Parenteral / instrumentation
  • Intubation, Intratracheal / instrumentation
  • Male
  • Phospholipids*
  • Prospective Studies
  • Pulmonary Surfactants / administration & dosage*
  • Respiration, Artificial
  • Respiratory Distress Syndrome, Newborn / complications
  • Respiratory Distress Syndrome, Newborn / drug therapy*
  • Respiratory Distress Syndrome, Newborn / therapy

Substances

  • Biological Products
  • Phospholipids
  • Pulmonary Surfactants
  • poractant alfa