Radiation dosimetry for indium-111-pentetreotide

J Nucl Med. 1997 Dec;38(12):1919-22.

Abstract

We present radiation dose estimates for 111In-pentetreotide.

Methods: Kinetic data were gathered in 10 subjects at two different sites. A compartmental model was used to fit the data, including retention, in three major organs and excretion.

Results: The data were consistent for the subjects at both sites. The organ receiving the highest dose was the kidneys (0.52 mGy/MBq); the effective dose equivalent was 0.1 mSv/MBq, and the effective dose was 0.073 mSv/MBq.

Conclusion: The results of this study provide the basis for evaluation of radiation safety of this drug.