Background: Therapeutic drug monitoring-informed teicoplanin dosage adjustments are recommended for safe and effective use. The authors' group previously reported that only half of children reached the recommended blood concentration range at the standard teicoplanin loading dose. It has been suggested that higher loading doses are necessary; however, the usefulness and safety of high-dose loading in pediatric patients in clinical practice are unknown.
Methods: This retrospective cohort study was conducted between January 2018 and June 2021 using electronic medical records. The analysis included 2- to 16-year-old patients treated with teicoplanin who met the eligibility criteria. We assessed the trough concentration of teicoplanin and its safety after high-dose loading in pediatric patients.
Results: Overall, 86 patients received a high-dose loading regimen (15 mg/kg every 12 hours for 3 doses, followed by 10 mg/kg once daily). Notably, 55 of the 86 patients (64%) achieved the target trough concentration (>15 mg/L) at significantly higher rates without increasing the incidence of organ damage compared with the standard loading regimen. Multivariate analysis revealed significant differences in age and renal function as factors that inhibited the attainment of the target trough concentration. Simulation analysis using a nomogram stratified by age and renal function revealed that the predicted teicoplanin trough levels were within the target trough values in 73% of patients.
Conclusions: High-dose teicoplanin loading safely increases trough blood concentrations in the pediatric population. For further optimization, the dose selection should be stratified according to age and renal function.
Copyright © 2025 Wolters Kluwer Health, Inc. All rights reserved.