Inorganic bioelectric system for nitrate removal with low N2O production at cold temperatures of 4 and 10 °C

Water Res. 2024 Dec 27:274:123061. doi: 10.1016/j.watres.2024.123061. Online ahead of print.

Abstract

Groundwater, essential for ecological stability and freshwater supply, faces escalating nitrate contamination. Traditional biological methods struggle with organic carbon scarcity and low temperatures, leading to an urgent need to explore efficient approaches for groundwater remediation. In this work, we proposed an inorganic bioelectric system designed to confront these challenges. At 10 and 4 °C, the system achieved total nitrogen (TN) removal efficiencies of 95.4 ± 2.7% and 90.9 ± 1.9% at 2 h hydraulic retention time (HRT), while maximum TN removal rates were recorded as 206.0 ± 6.3 and 178.3 ± 9.4 g N·m-3·d-1 at 1 h HRT. The microbial analysis uncovered shifts in dominant genera across temperatures, with Dechloromonas prevalent at 10 °C and Chryseobacterium at 4 °C, highlighting adaptability to cold-tolerant species. Gene analysis on narG, napA, nirS, nirK, norB, nosZI, nosZII, and nifA examined the nitrate reduction processes, and analysis on mtrC and omcA hinted at electrotrophic processes. Additionally, we demonstrated system resilience to disruptions of power outage and short periods without flow through. These findings establish a foundational understanding of electricity-driven nitrate bioreduction in cold environments, crucial in groundwater remediation strategies and paving the way for future optimization and upscaling efforts.

Keywords: Autotrophic denitrification; Bioelectric reactor; Denitrifier; Gene analysis; Low temperature; Microbial analysis; Nitrous oxide emissions.