Antihypertensive pharmacological therapy is often characterized by a coadministration of different classes of drugs. Therefore, analytical methods allowing the simultaneous quantification of many drugs are needed for therapeutic drug monitoring (TDM) purposes in this context. In particular, TDM represents a useful tool to discriminate poor adherence from real cases of resistant hypertension. For this reason, the aim of this study is to validate, following the Food and Drug Administration (FDA) and the European Medicines Agency (EMA) guidelines, an ultrahigh-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous quantification of 18 antihypertensive drugs in human plasma. A LX-50 coupled with a QSight 220 UHPLC-MS/MS system with electrospray ionization and multiple reaction monitoring mode was used, after a binary gradient separation (13 min) on a reverse-phase Acquity UPLC HSS T3 [1.8 μm, 2.1 mm × 150 mm] column. Method validation showed a stable and acceptable matrix effect, recovery, high accuracy, and precision, assessing the eligibility of this method for routine use in the clinical context.