Abstract

Electrophysiological examinations are used in ophthalmology to determine the functionality of the neurons of the visual pathway. As electrophysiological examinations are independent of the subjective perception and response of the patient, they are considered to be objective functional diagnostics of vision. Electroretinography (ERG) is used to examine the retina (especially the photoreceptors), electro-oculography (EOG) is used to examine the functionality of the retinal pigment epithelium and visually evoked potentials (VEP) are used to evaluate the integrity of the entire visual pathway. Abnormalities in electrophysiological responses should always be interpreted in the context of other functional and morphological findings.

Mit elektrophysiologischen Untersuchungen kann man in der Augenheilkunde die Funktionalität der Neurone der Sehbahn untersuchen. Weil elektrophysiologische Ableitungen von der subjektiven Wahrnehmung und Antwort des Patienten unabhängig sind, gelten sie als objektive Funktionsdiagnostik des Sehens. Die Elektroretinographie (ERG) dient der Untersuchung der Netzhaut, die Elektrookulographie (EOG) der Untersuchung des retinalen Pigmentepithels, und visuell evozierte Potenziale (VEP) dienen der Evaluierung der gesamten Sehbahn. Elektrophysiologische Antworten sollten immer im Kontext der restlichen Befunde interpretiert werden.

Keywords: Electro-oculography; Electroretinography; Neurons; Visual pathway; Visually evoked potentials.

Publication types

  • English Abstract
  • Review

MeSH terms

  • Electrooculography*
  • Electroretinography* / methods
  • Evoked Potentials, Visual* / physiology
  • Humans
  • Ophthalmology / methods
  • Retina / physiopathology
  • Retinal Diseases / diagnosis
  • Retinal Diseases / physiopathology
  • Visual Pathways