Objective: This non-interventional, prospective, single-center study aimed to develop a technique to measure ruxolitinib (RUX) concentrations and provide preliminary data on the distribution of plasma drug levels in patients with steroid refractory (SR) GvHD.
Methods: Between April 2023 and May 2024, we analyzed 48 blood samples from 29 patients with SR-GvHD.
Results: Median individual plasma concentrations varied across different RUX doses and largely overlapped: 39.2 ng/mL at 10 mg b.i.d (range: 0-73), 13.1 ng/mL at 10-5 mg (range, 6.1-35.6), and 31.6 ng/mL at 5 mg b.i.d (range: 0.7-99.9). Samples taken under non-optimal temperature conditions showed a lower median concentration of 0.77 ng/mL (range: 0-7.4 ng/mL). The four patients who did not respond at days +28 and +180 after RUX initiation (3 with lower gastrointestinal aGvHD, and 1 with ocular, hepatic, and pulmonary cGvHD) showed a median concentration of only (7.4 ng/mL (range, 0-29) ng/mL) with full dosing.
Conclusions: The introduction and validation of a liquid chromatography-tandem mass spectrometry method for quantifying plasma RUX concentrations was feasible in our center. Administering predetermined and fixed doses of RUX in patients with SR-GvHD showed highly variable and overlapping plasma drug concentrations. This underscores the potential importance of RUX- pharmacokinetics (PK) monitoring.
Keywords: GvHD; Ruxolitinib; allogeneic hematopoietic cell transplant; therapeutic drug‐monitoring.
© 2024 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.