Intravenous (IV) digoxin loading dose recommendations for rate control of atrial arrhythmias in critically ill patients are not well studied. When using digoxin in the setting of atrial fibrillation/atrial flutter (AF/AFL), a loading dose (LD) in either a fixed-dose regimen, weight-based dose, or pharmacokinetic-based calculation to target a serum digoxin concentration (SDC) of 0.8-1.5 ng/mL is recommended. The objective of this study was to assess the safety and effectiveness of digoxin LD used in critically ill patients for rate control of AF/AFL and to assess the SDC achieved. This single center retrospective cohort study included patients who received IV digoxin and had a SDC drawn. The primary endpoint was the median SDC achieved after a digoxin LD. Secondary outcomes included the frequency of SDCs ≥1.5 ng/mL and heart rate (HR) control. A total of 92 patients were included. The median total LD of digoxin for the entire cohort was 11mcg/kg (750 mcg). For 61% of the cohort, the LD was distributed over six-hour intervals. The median SDC after completion of the IV digoxin LD was 1.3 ng/mL (0.9, 1.7). The incidence of supratherapeutic SDC was 36% for the total cohort. A target HR < 110 beats per minute within 24 hours from digoxin LD was achieved in 60% of the cohort. In conclusion, a median total digoxin LD of 750 mcg in critically ill patients with AF/AFL, targeting a SDC < 1.5ng/mL may be considered for acute rate control, taking into account drug-drug interactions in the cardiac intensive care unit. Future studies are necessary to confirm our findings.
Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.