Impact of kV-cone beam computed tomography dose on DNA repair mechanisms: A pilot study

Cancer Radiother. 2024 Oct;28(5):449-452. doi: 10.1016/j.canrad.2024.05.001. Epub 2024 Sep 17.

Abstract

Purpose: In head and neck squamous cell carcinoma (HNSCC), early complications of the radiotherapy (RT) are observed from the beginning of the treatment to a few months after its end. During external radiotherapy treatment, several patient-dependent parameters can cause a modification of the dose distribution compared to the planned distribution due to variation in patient positioning, anatomy, or intra-fractional movements for example. To verify these parameters during treatment sessions, one of the most commonly used solutions is the cone-beam computed tomography (CBCT). Nowadays, the use of CBCT may constitutes a significant part of the total dose at the end of treatment (up to 10 cGy per session) and more often the volume irradiated by imaging is larger than the one irradiated by the treatment, leading to unintentional irradiation of nearby organs. In this study, we asked whether the imaging low dose added to a following fraction dose (2Gy) may affect the biological response in terms of DNA repair.

Material and methods: Using an IVInomad dosimeter and scintillating fiber probes specially designed for this exploratory study, we exposed fibroblasts cells from head and neck cancer (HNC) patients to a CBCT dose followed by a radiotherapy fraction dose. DNA double strand breaks and DNA repair were assessed by immunofluorescence using the biomarkers gamma H2AX (γH2AX) and pATM.

Results: The median dose of CBCT was measured between 17 to 21 mGy per session. The kinetics of both biomarkers were found to be strongly dependent on the individual factor in radiosensitive patients. For HNC patients, a prior CBCT dose applied few minutes before the 2Gy dose may have a sublinear effect on the DNA repair mechanisms and potentially on observed health tissue toxicity.

Conclusion: The preliminary results obtained highlight the importance of individual and tissue factors for recognizing and repairing DSB during a treatment by radiotherapy using CBCT.

Keywords: Cancer; DNA repair; Dosimètre à scintillation; Fibre optique; Optical fiber; Radiosensibilité; Radiosensitivity; Radiotherapy; Radiothérapie; Réparation de l’ADN; Scintillating dosimetry; pATM.

MeSH terms

  • Carcinoma, Squamous Cell / diagnostic imaging
  • Carcinoma, Squamous Cell / radiotherapy
  • Cone-Beam Computed Tomography* / methods
  • DNA Breaks, Double-Stranded
  • DNA Repair*
  • Fibroblasts / radiation effects
  • Head and Neck Neoplasms* / diagnostic imaging
  • Head and Neck Neoplasms* / radiotherapy
  • Histones / metabolism
  • Humans
  • Pilot Projects
  • Radiotherapy Dosage
  • Squamous Cell Carcinoma of Head and Neck / diagnostic imaging
  • Squamous Cell Carcinoma of Head and Neck / radiotherapy

Substances

  • Histones
  • H2AX protein, human