Evaluation of Xpert point-of-care assays for detection of HIV infection in persons using long-acting cabotegravir for pre-exposure prophylaxis

Microbiol Spectr. 2024 Jul 9;12(8):e0030724. doi: 10.1128/spectrum.00307-24. Online ahead of print.

Abstract

Detection of HIV infection may be challenging in persons using long-acting cabotegravir (CAB-LA) pre-exposure prophylaxis (PrEP) due to viral suppression and reduced/delayed antibody production. We evaluated two point-of-care tests for detecting HIV infection in persons who received CAB-LA in the HPTN 083 trial. Samples were obtained from 12 participants who received CAB-LA and had delayed detection of HIV infection using HIV rapid tests and an antigen/antibody test (52 plasma samples; 18 dried blood spot [DBS] samples). Plasma samples were tested with the Xpert HIV-1 Viral Load XC test (Xpert VL-XC); DBS samples were tested with the total nucleic acid Xpert HIV-1 Qual XC test (Xpert Qual-XC). Results from these assays were compared to results from three reference, laboratory-based, plasma RNA assays (Aptima HIV-1 Qualitative assay [Aptima Qual]; Aptima HIV-1 Quant DX Assay [Aptima Quant]; cobas HIV-1/HIV-2 Qualitative Test [cobas]). HIV RNA was detected with all four plasma assays for all samples with viral loads (VLs) ≥ 200 copies/mL; the number of samples with VLs < 200 copies/mL with HIV RNA detected was: Xpert VL-XC: 19/26 (73.1%); Aptima Qual: 17/26 (65.4%); Aptima Quant: 17/26 (65.4%); and cobas: 12/21 (57.1%). The Xpert Qual-XC assay was positive for all DBS samples with VLs ≥ 200 copies/mL and 1/10 DBS with VLs < 200 copies/mL. The performance of the Xpert VL-XC assay was comparable to the reference assays for detecting HIV infection in these cases. The Xpert Qual-XC assay was less sensitive than plasma-based HIV RNA assays for detecting HIV in the setting of CAB-LA PrEP.

Importance: HIV RNA assays can detect HIV infections earlier than HIV rapid tests or Ag/Ab tests in persons using CAB-LA PrEP. Earlier HIV diagnosis could allow for earlier treatment initiation and reduced risk of INSTI resistance. POC tests may help detect HIV infection before CAB-LA administration and may be more accessible than laboratory-based assays in some settings. In this study, the POC Xpert VL-XC assay detected HIV RNA in most samples from individuals who received CAB-LA PrEP and had delayed detection of HIV infection with HIV rapid tests and an Ag/Ab test. The performance of this assay was similar to laboratory-based HIV RNA assays in this cohort. The POC Xpert Qual-XC assay detects both HIV RNA and DNA, with a higher viral load cutoff for RNA detection. This assay was negative for most lower viral load samples and did not offer an advantage for HIV screening in persons using CAB-LA PrEP.

Keywords: HIV prevention; HPTN 083; RNA; long-acting cabotegravir; point-of-care; pre-exposure prophylaxis.