Diagnostic accuracy of contrast-enhanced CT versus PET/CT for advanced ovarian cancer staging: a comparative systematic review and meta-analysis

Abdom Radiol (NY). 2024 Jun;49(6):2135-2144. doi: 10.1007/s00261-024-04195-x. Epub 2024 Mar 25.

Abstract

Purpose: Accurate staging of ovarian cancer is critical to guide optimal management pathways. North American guidelines recommend contrast-enhanced CT as the primary work-up for staging ovarian cancer. This meta-analysis aims to compare the diagnostic accuracy of contrast-enhanced CT alone to PET/CT for detecting abdominal metastases in patients with a new or suspected diagnosis of ovarian cancer.

Materials and methods: A systematic review of MEDLINE, EMBASE, Scopus, the Cochrane Library, and the gray literature from inception to October 2022 was performed. Studies with a minimum of 5 patients evaluating the diagnostic accuracy of contrast-enhanced CT and/or PET/CT for detecting stage 3 ovarian cancer as defined by a surgical/histopathological reference standard ± clinical follow-up were included. Study, clinical, imaging, and accuracy data for eligible studies were independently acquired by two reviewers. Primary meta-analysis was performed in studies reporting accuracy on a per-patient basis using a bivariate mixed-effects regression model. Risk of bias was evaluated using QUADAS-2.

Results: From 3701 citations, 15 studies (918 patients with mean age ranging from 51 to 65 years) were included in the systematic review. Twelve studies evaluated contrast-enhanced CT (6 using a per-patient assessment and 6 using a per-region assessment) and 11 studies evaluated PET/CT (7 using a per-patient assessment and 4 using a per-region assessment). All but one reporting study used consensus reading. Respective sensitivity and specificity values on a per-patient basis were 82% (67-91%, 95% CI) and 72% (59-82%) for contrast-enhanced CT and 87% (75-94%) and 90% (82-95%) for PET/CT. There was no significant difference in sensitivities between modalities (p = 0.29), but PET/CT was significantly more specific than CT (p < 0.01). Presumed variability could not be assessed in any single category due to limited studies using per-patient assessment. Studies were almost entirely low risk for bias and applicability concerns using QUADAS-2.

Conclusion: Contrast-enhanced CT demonstrates non-inferior sensitivity compared to PET/CT, although PET/CT may still serve as an alternative and/or supplement to CT alone prior to and/or in lieu of diagnostic laparoscopy in patients with ovarian cancer. Future revisions to existing guidelines should consider these results to further refine the individualized pretherapeutic diagnostic pathway.

Keywords: Accuracy; Computed tomography; Mucinous; Ovarian cancer; Positron emission tomography; Sensitivity; Serous; Specificity; Staging.

Publication types

  • Systematic Review
  • Meta-Analysis
  • Comparative Study

MeSH terms

  • Contrast Media*
  • Female
  • Humans
  • Neoplasm Staging*
  • Ovarian Neoplasms* / diagnostic imaging
  • Ovarian Neoplasms* / pathology
  • Positron Emission Tomography Computed Tomography* / methods
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed* / methods

Substances

  • Contrast Media