Fetal magnetic resonance imaging, ultrasound, and echocardiography findings in twin reversed arterial perfusion sequence

Pediatr Radiol. 2024 May;54(5):702-714. doi: 10.1007/s00247-024-05879-8. Epub 2024 Mar 15.

Abstract

Background: Twin reversed arterial perfusion (TRAP) sequence is a rare complication of monochorionic multiple gestation pregnancies, in which the pump twin provides hemodynamic support to a nonviable co-twin (acardius). Fetal magnetic resonance imaging (MRI) is used to detect pump twin abnormalities, particularly brain ischemia, prior to fetal intervention to interrupt umbilical blood flow to the acardius.

Objective: To summarize the imaging findings of TRAP sequence pregnancies in a large series.

Materials and methods: A single-center retrospective review was performed of all TRAP sequence pregnancies referred for fetal MRI (2004-2021). Fetal MRI, ultrasound, and echocardiography data were collected.

Results: Eighty-eight TRAP sequence pregnancies with MRI were included (mean gestational age, 19.8±2.8 weeks). Demise of the pump twin was noted in two pregnancies at the time of MRI. By MRI, 12% (10/86) of live pump twins had abnormalities, including 3% (3/86) with brain abnormalities and 9% (8/86) with extra-cranial abnormalities. By echocardiography, 7% (6/86) of pump twins had structural cardiac abnormalities. Three acardius morphological subtypes were identified by MRI: acephalus (55%, 48/88), anceps (39%, 34/88), and amorphous (7%, 6/88). The mean ultrasound acardius to pump twin ratio A/P ratio, calculated for each twin pair as the ratio of the acardius trunk (and head, if present) plus limb volume to the pump twin estimated fetal weight) differed among the three acardius subtypes (P=.03). The mean A/P ratio moderately correlated with pump twin cardiothoracic ratio and combined cardiac output (Pearson's r=0.45 and 0.48, respectively, both P<.001).

Conclusion: Fetal MRI of TRAP sequence pregnancies found anomalies in a substantial number of pump twins. The three acardius subtypes differed in A/P ratio, which moderately correlated with the pump twin cardiothoracic ratio and combined cardiac output.

Keywords: Acardius; Fetal magnetic resonance imaging; Feto fetal transfusion; Pump twin; Twin reversed arterial perfusion sequence.

MeSH terms

  • Adult
  • Echocardiography* / methods
  • Female
  • Fetofetal Transfusion* / diagnostic imaging
  • Humans
  • Magnetic Resonance Imaging* / methods
  • Pregnancy
  • Pregnancy, Twin
  • Prenatal Diagnosis / methods
  • Retrospective Studies
  • Ultrasonography, Prenatal* / methods