Assessment of Mobility Trajectories Using Wearable Inertial Sensors During Autologous Hematopoietic Cell Transplant

Arch Phys Med Rehabil. 2024 Jun;105(6):1106-1115. doi: 10.1016/j.apmr.2024.01.019. Epub 2024 Feb 12.

Abstract

Objective: This study aimed to characterize mobility patterns using wearable inertial sensors and serial assessment across autologous hematopoietic cell transplant (autoHCT) and investigate the relation between mobility and perceived function in patients with hematologic cancer.

Design: Prospective longitudinal study.

Setting: Hospital adult transplant clinic followed by discharge.

Participants: 78 patients with hematological cancer receiving autoHCT.

Main outcome measures: Mobility was measured across 3 clinical phases (pretransplant, pre-engraftment, and post-engraftment) in using inertial sensors worn during prescribed performance tests in the hospital. Perceived function was assessed using validated provider-reported (Eastern Cooperative Oncology Group [ECOG] Performance Status Scale) and patient-reported [European Organization for Research and Treatment of Cancer Quality of Life Questionnaire [EORTC QLQ-C30]) measures. Trajectories of 5 selected mobility characteristics (turn duration, gait speed, stride time variability, double support time, and heel strike angle) across the clinical phases were also evaluated using piecewise linear mixed-effects models.

Results: Using Principal Components Analysis, 4 mobility patterns were identified pretransplant: Gait Limitation, Sagittal Sway, Coronal Sway, and Balance Control. Gait Limitation measured pretransplant was significantly inversely associated with perceived function reported by the provider- (β = -0.11; 95% CI: -0.19, -0.02) and patient- (β = -4.85; 95% CI: -7.72, -1.99) post-engraftment in age-adjusted linear regression models. Mobility characteristics demonstrated immediate declines early pre-engraftment with stabilization by late pre-engraftment.

Conclusion: Patients with hematological cancer experiencing gait limitations pretransplant are likely to have worse perceived function post-engraftment. Mobility declines in early phases post-transplant and may not fully recover, indicating an opportunity for timely rehabilitation referrals. Wearable inertial sensors can be used to identify early mobility problems and patients who may be at risk for future functional decline who may be candidates for early physical rehabilitation.

Keywords: Disability; Gait analysis; Hematologic neoplasms; Multiple myeloma; Physical functional performance; Postural balance; Rehabilitation.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Female
  • Hematologic Neoplasms* / rehabilitation
  • Hematopoietic Stem Cell Transplantation*
  • Humans
  • Longitudinal Studies
  • Male
  • Middle Aged
  • Mobility Limitation
  • Postural Balance / physiology
  • Prospective Studies
  • Quality of Life
  • Transplantation, Autologous
  • Walking Speed / physiology
  • Wearable Electronic Devices*