Maternal hemodynamic evaluation in monochorionic twin pregnancy complicated by twin-to-twin transfusion syndrome treated with fetoscopic laser surgery

Am J Obstet Gynecol MFM. 2024 Mar;6(3):101270. doi: 10.1016/j.ajogmf.2023.101270. Epub 2023 Dec 23.

Abstract

Background: Maternal cardiovascular adaptations are amplified in twin pregnancies to support the metabolic request of the feto-placental unit. Few studies have evaluated the maternal hemodynamics changes after routine use of laser surgery in the treatment of twin-twin transfusion syndrome.

Objective: The aim of our study was to evaluate hemodynamic changes in monochorionic twin pregnancies complicated by twin-twin transfusion syndrome before and after treatment with fetoscopic laser surgery.

Study design: A prospective observational study from 2020 to 2022, included monochorionic twin pregnancies complicated with twin-twin transfusion syndrome undergoing laser surgery between 16 and 26 weeks of gestation. To assess placental function and perfusion, uterine artery pulsatility index, hemoglobin, hematocrit, and soluble fms-like tyrosine kinase-1/placental growth factor ratio sampling prelaser and 24 hours postlaser were measured. Echocardiography by a single cardiologist evaluated maternal hemodynamics at presurgery, 24 hours, and 1 week postlaser. Those data were crosswise compared with cardiovascular indices of uncomplicated monochorionic pregnancies recruited at the same gestational age using nonparametric tests. Moreover, we fitted random-intercept linear regression models to investigate maternal hemodynamic changes according to the amount of amniotic fluid drained during laser surgery.

Results: Forty-two twin-twin transfusion syndrome pregnancies with a median gestational age of 19.1 (17.4-20.9) weeks and 15 uncomplicated monochorionic pregnancies at the same gestational age were enrolled. Overall survival rate after laser was 72% with delivery at a median gestational age of 31.5 (27-34) weeks. Significant changes in blood chemistry and placental function were observed in the twin-twin transfusion syndrome group, along with alterations in arterial pressure, heart rate, cardiac output, and ventricular strain, eventually aligning with the uncomplicated group's values by 1 week postlaser. The amount of amniodrainage, with a 1000 ml cut-off, did not significantly impact hemodynamic parameters. Lastly, we detected a percentage of laser surgery complications in agreement with international literature and we did not record any maternal procedure-related problems.

Conclusion: Our analysis highlighted that maternal cardiovascular status in monochorionic twin pregnancy complicated by twin-twin transfusion syndrome was more dynamic and; 1 week after fetoscopic laser ablation of placental anastomosis completed by amniodrainage, maternal hemodynamic parameters restored to values similar to uncomplicated monochorionic twin pregnancies.

Keywords: fetoscopic laser ablation; maternal hemodynamics; monochorionic pregnancy; twin-to-twin transfusion syndrome.

Publication types

  • Observational Study

MeSH terms

  • Female
  • Fetofetal Transfusion* / diagnosis
  • Fetofetal Transfusion* / surgery
  • Hemodynamics
  • Humans
  • Infant
  • Laser Therapy* / adverse effects
  • Lasers
  • Placenta
  • Placenta Growth Factor
  • Pregnancy
  • Pregnancy, Twin

Substances

  • Placenta Growth Factor