Perioperative peri-implant fracture after osteosynthesis for geriatric femoral pertrochanteric fracture with the linear compression integrated screw intramedullary nail system (INTERTAN™): a retrospective study

J Orthop Surg Res. 2023 Dec 6;18(1):932. doi: 10.1186/s13018-023-04441-w.

Abstract

Background: Osteosynthesis for geriatric femoral pertrochanteric fractures using the linear compression integrated screw intramedullary nail system (INTERTAN™) has become popular. Nonetheless, cases of perioperative peri-implant fractures have been reported following this surgical technique. The factors responsible for this complication remain unclear. Therefore, we investigated perioperative peri-implant fracture risk factors and incidence, as well as overall outcomes, using the INTERTAN™ system for geriatric femoral pertrochanteric fractures.

Methods: We retrospectively reviewed 98 consecutive patients with geriatric femoral pertrochanteric fractures after INTERTAN™ fixation, with at least a 12-month follow-up period between May 2020 and April 2022 at a single medical institute. The patients' demographic characteristics, fracture pattern, quality of reduction, quality of fixation, nail length, morphology of the femur, and perioperative complications were recorded and analyzed.

Results: Among the 98 patients, 92 achieved union during follow-up. Twelve perioperative peri-implant fractures (12.2%) were recorded, all of which occurred during or within 1 month of osteosynthesis. Except for one patient who underwent re-osteosynthesis, the others underwent nonoperative treatment, and all achieved union. Multiple regression analysis revealed morphology of the femur with low-lesser trochanter width (odds ratio (OR) 0.532, 95% confidence interval (CI) 0.33-0.86, p = 0.01) to be the only factor contributing to perioperative peri-implant fractures. When the Youden index was used, the optimal cut-off value was 20.2 mm of low-lesser trochanter width. Low-lesser trochanter width < 20.2 mm was found to be a potential factor causing perioperative peri-implant fractures (OR 17.81, 95% CI 1.67-19.76, p = 0.017).

Conclusions: Morphology of the femur with a low-lesser trochanter width smaller than 20.2 mm was found to be the only potential contributor to perioperative peri-implant fractures when using INTERTAN™ for geriatric femoral pertrochanteric fractures. Care should be taken during osteosynthesis, focusing not only on the fracture site but also on the femoral cortex around the implant. Although perioperative peri-implant fractures were observed within one month following osteosynthesis, the majority of these cases were effectively treated without surgical intervention.

Keywords: Bone screws; Femoral fractures; Femur; Periprosthetic fractures.

MeSH terms

  • Aged
  • Bone Nails / adverse effects
  • Bone Screws / adverse effects
  • Femoral Fractures* / surgery
  • Femur
  • Fracture Fixation, Internal / adverse effects
  • Fracture Fixation, Internal / methods
  • Fracture Fixation, Intramedullary* / adverse effects
  • Hip Fractures* / complications
  • Hip Fractures* / surgery
  • Humans
  • Periprosthetic Fractures* / etiology
  • Retrospective Studies