Aim: To evaluate the effect of faster aspart over glycaemic variability in type 1 diabetes (T1D) patients treated with sensor-augmented pump (SAP) in a real-world scenario.
Methods: Observational study with SAP-treated adult T1D patients treated with faster aspart for three months. The primary endpoint was the mean amplitude of glucose excursions (MAGE).
Results: Fifty patients were treated with faster aspart. Eleven patients (23%) withdrew during the follow-up mainly due to worsening of diabetes control (9 patients). Mean age was 41.2 yrs. (range 21-59) and T1D duration 22.4±10.0 yrs. Mean SAP treatment duration was 3.6±3.1 yrs. We detected a reduction of -7.0 (95% CI -1.1, -12.9; p=0.021) in MAGE at the end of the study. Other glycemic variability indices were also improved: standard deviation of mean interstitial glucose (-3mg/dl; 95% CI, -1, -5; p=0.01), CONGA4 (-2.2; 95% CI -0.3, -4.2; p=0.029), CONGA6 (-2.6; 95% CI -0.6, -4.6; p=0.011), GRADE (-0.5; 95% CI -0.1, -0.9; p=0.022), HBGI (-0.7; 95% CI -0.2, -1.3; p=0.013), J-index (-2.9; 95% CI -0.7, -5.0; p=0.011) and MODD (-5.7; 95% CI -1.7, -9.7; p=0.006). A slight reduction in mean glucose management indicator was also detected (-0.14%; 95% CI, -0.02, -0.27; -1.4mmol/mol; 95% CI -0.1, -3.3; p=0.03).
Conclusions: In SAP-treated T1D patients, faster aspart insulin was associated with reduced glycaemic variability, but also a high percentage of dropouts due to worsened glycaemic control. NCT04233203.
Keywords: Bomba de insulina; Diabetes mellitus tipo 1; Faster-acting insulin aspart; Glycaemic variability; Insulin pump; Insulina faster-aspart; Tratamiento; Treatment; Type 1 diabetes; Variabilidad glucémica.
Copyright © 2022 SEEN and SED. Published by Elsevier España, S.L.U. All rights reserved.