Efficacy and Safety of Axiostat® Hemostatic Dressing in Aiding Manual Compression Closure of the Femoral Arterial Access Site in Patients Undergoing Endovascular Treatments: A Preliminary Clinical Experience in Two Centers

J Pers Med. 2023 May 11;13(5):812. doi: 10.3390/jpm13050812.

Abstract

Background: Hemostasis of the femoral arterial access site by manual compression or a vascular closure device is critical to the safe completion of any endovascular procedure. Previous investigations evaluated the hemostatic efficacy at the radial access site of some chitosan-based hemostatic pads. This study aims to assess the efficacy and safety of a new chitosan-based hemostatic dressing, namely Axiostat®, in aiding manual compression closure of the femoral arterial access site in patients undergoing endovascular treatments. Furthermore, the outcomes were compared with evidence on manual compression alone and vascular closure devices.

Methods: This investigation is a two-center retrospective analysis of 120 consecutive patients who had undergone, from July 2022 to February 2023, manual compression closure of the femoral arterial access site aided by the Axiostat® hemostatic dressing. Endovascular procedures performed with introducer sheaths ranging from 4 Fr to 8 Fr were evaluated.

Results: Primary technical success was achieved in 110 (91.7%) patients, with adequate hemostasis obtained in all cases of prolonged manual compression requirements. The mean time-to-hemostasis and time-to-ambulation were 8.9 (±3.9) and 462 (±199) minutes, respectively. Clinical success was achieved in 113 (94.2%) patients, with bleeding-related complications noted in 7 (5.8%) patients.

Conclusions: Manual compression aided by the Axiostat® hemostatic dressing is effective and safe in achieving hemostasis of the femoral arterial access site in patients undergoing endovascular treatment with a 4-8 Fr introducer sheath.

Keywords: VASC; bleeding-related complications; common femoral artery; femoral arterial access site; hemostasis; hemostatic dressing; hemostatic pad; manual compression; vascular access site; vascular access site complications.

Grants and funding