Objectives: To investigate whether a multi-item performance outcome measure, the physical performance test (PPT), can be calibrated to a common scale with patient-reported outcome measures, using the Patient-Reported Outcomes Measurement Information System (PROMIS) physical function (PF) metric.
Study design and setting: We analyzed baseline data (N = 1,113) from the CONVINCE study, an international trial in end-stage kidney disease patients comparing high-dose hemodiafiltration with high-flux hemodialysis. Assumptions of item response theory (IRT) modelling were investigated for the combined set of the nine-item PPT and a four-item PROMIS PF short form (PROMIS-PF4a). We applied unidimensional IRT linking for calibrating the PPT to the PROMIS PF metric.
Results: Although some evidence for multidimensionality was found, classical test statistics (Cronbach's Alpha = 0.93), Mokken (Loevinger's H = 0.50), and bifactor analysis (explained common variance = 0.65) indicated that PPT and PROMIS-PF4a items can be used to assess a common PF construct. On the group level, the agreement between PROMIS-PF4a and linked PPT scores was stable across several subsamples. On the individual level, scores differed considerably.
Conclusion: We found preliminary evidence that the PPT can be linked to the PROMIS PF metric in hemodialysis patients, enabling group comparisons across patient-reported outcome and performance outcome measures. Alternative linking methods should be applied in future studies using a more comprehensive PROMIS PF item set.
Keywords: Clinical outcome assessment; Hemodialysis; Linking; Patient-reported outcomes; Performance outcomes; Physical function.