Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation

Phys Med Biol. 2023 May 11;68(10). doi: 10.1088/1361-6560/acccce.

Abstract

Daily cone beam computed tomography (CBCT) imaging during the course of fractionated radiotherapy treatment can enable online adaptive radiotherapy but also expose patients to a non-negligible amount of radiation dose. This work investigates the feasibility of low dose CBCT imaging capable of enabling accurate prostate radiotherapy dose calculation with only 25% projections by overcoming under-sampling artifacts and correcting CT numbers by employing cycle-consistent generative adversarial networks (cycleGAN). Uncorrected CBCTs of 41 prostate cancer patients, acquired with ∼350 projections (CBCTorg), were retrospectively under-sampled to 25% dose images (CBCTLD) with only ∼90 projections and reconstructed using Feldkamp-Davis-Kress. We adapted a cycleGAN including shape loss to translate CBCTLDinto planning CT (pCT) equivalent images (CBCTLD_GAN). An alternative cycleGAN with a generator residual connection was implemented to improve anatomical fidelity (CBCTLD_ResGAN). Unpaired 4-fold cross-validation (33 patients) was performed to allow using the median of 4 models as output. Deformable image registration was used to generate virtual CTs (vCT) for Hounsfield units (HU) accuracy evaluation on 8 additional test patients. Volumetric modulated arc therapy plans were optimized on vCT, and recalculated on CBCTLD_GANand CBCTLD_ResGANto determine dose calculation accuracy. CBCTLD_GAN, CBCTLD_ResGANand CBCTorgwere registered to pCT and residual shifts were analyzed. Bladder and rectum were manually contoured on CBCTLD_GAN, CBCTLD_ResGANand CBCTorgand compared in terms of Dice similarity coefficient (DSC), average and 95th percentile Hausdorff distance (HDavg, HD95). The mean absolute error decreased from 126 HU for CBCTLDto 55 HU for CBCTLD_GANand 44 HU for CBCTLD_ResGAN. For PTV, the median differences ofD98%,D50%andD2%comparing both CBCTLD_GANto vCT were 0.3%, 0.3%, 0.3%, and comparing CBCTLD_ResGANto vCT were 0.4%, 0.3% and 0.4%. Dose accuracy was high with both 2% dose difference pass rates of 99% (10% dose threshold). Compared to the CBCTorg-to-pCT registration, the majority of mean absolute differences of rigid transformation parameters were less than 0.20 mm/0.20°. For bladder and rectum, the DSC were 0.88 and 0.77 for CBCTLD_GANand 0.92 and 0.87 for CBCTLD_ResGANcompared to CBCTorg, and HDavgwere 1.34 mm and 1.93 mm for CBCTLD_GAN, and 0.90 mm and 1.05 mm for CBCTLD_ResGAN. The computational time was ∼2 s per patient. This study investigated the feasibility of adapting two cycleGAN models to simultaneously remove under-sampling artifacts and correct image intensities of 25% dose CBCT images. High accuracy on dose calculation, HU and patient alignment were achieved. CBCTLD_ResGANachieved better anatomical fidelity.

Keywords: Low dose CBCT; adaptive therapy; cycleGAN.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cone-Beam Computed Tomography
  • Feasibility Studies
  • Humans
  • Image Processing, Computer-Assisted / methods
  • Male
  • Prostate
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / methods
  • Radiotherapy, Intensity-Modulated*
  • Retrospective Studies
  • Spiral Cone-Beam Computed Tomography*