MiniMed 780G™ in 2- to 6-Year-Old Children: Safety and Clinical Outcomes After the First 12 Weeks

Diabetes Technol Ther. 2023 Feb;25(2):100-107. doi: 10.1089/dia.2022.0313. Epub 2022 Dec 30.

Abstract

Objective: The safety and impact of the advanced hybrid closed-loop (AHCL) system on glycemic outcome in 2- to 6-year-old children with type 1 diabetes and the diabetes distress of caregivers were evaluated. Research Design and Methods: This was an open-label prospective study (n = 35) with historical controls matched by treatment unit, diabetes duration, age, gender, and baseline treatment modality. The inclusion criteria were (1) type 1 diabetes diagnosis >6 months, (2) total daily dose of insulin ≥8 U/day, (3) HbA1c <10% (85 mmol/mol), and (4) capability to use insulin pump and continuous glucose monitoring. The MiniMed 780G™ AHCL in SmartGuard™ Mode was used for 12 weeks. Parental diabetes distress was evaluated with a validated Problem Areas In Diabetes-Parent, revised (PAID-PR) survey. Results: No events of diabetic ketoacidosis or severe hypoglycemia occurred. Between 0 and 12 weeks, HbA1c (mean change = -2.7 mmol/mol [standard deviation 5.7], P = 0.010), mean sensor glucose value (SG) (-0.8 mmol/L [1.0], P < 0.001), and time above range (TAR) (-8.6% [9.5], P < 0.001) decreased and time in range (TIR) (8.3% [9.3], P < 0.001) increased significantly, whereas no significant change in time below range (TBR) was observed. At the same time, PAID-PR score decreased from 37.5 (18.2) to 27.5 (14.8) (P = 0.006). Conclusions: MiniMed 780G™ AHCL is a safe system and 12-week use was associated with improvements in glycemic control in 2- to 6-year-old children with type 1 diabetes. In addition, AHCL is associated with a reduction in parental diabetes distress after 12-week use. ClinicalTrials.gov registration number: NCT04949022.

Keywords: Advanced HCL; Hybrid closed-loop; Type 1 diabetes; Young children.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Blood Glucose
  • Blood Glucose Self-Monitoring
  • Child
  • Diabetes Mellitus, Type 1* / complications
  • Diabetes Mellitus, Type 1* / drug therapy
  • Glycated Hemoglobin
  • Humans
  • Hypoglycemic Agents / therapeutic use
  • Insulin / adverse effects
  • Insulin Infusion Systems
  • Prospective Studies
  • Treatment Outcome

Substances

  • Blood Glucose
  • Glycated Hemoglobin
  • Hypoglycemic Agents
  • Insulin

Associated data

  • ClinicalTrials.gov/NCT04949022