Many quality improvement interventions do not lead to sustained improvement, and the sustainability of healthcare interventions remains understudied. We conducted a time-series analysis to determine whether improvements in the safety of rapid sequence intubation (RSI) in our academic pediatric emergency department were sustained 5 years after a quality improvement initiative.
Methods: There were 3 study periods: baseline (April 2009-March 2010), improvement (July 2012-December 2013), and operational (January 2014-December 2018). All patients undergoing RSI were eligible. We collected data using a structured video review. We compared key processes and outcomes with statistical process control charts.
Results: We collected data for 615 of 643 (96%) patient encounters with RSI performed: 114 baseline (12 months), 105 improvement (18 months), and 396 operational (60 months). Key characteristics were similar, including patient age. Statistical process control charts indicated sustained improvement of all 6 key processes and the primary outcome measure (oxyhemoglobin desaturation) throughout the 5-year operational period.
Conclusions: Improvements in RSI safety were sustained 5 years after a successful improvement initiative, with further improvement seen in several key processes. Further research is needed to elucidate the factors contributing to sustainability.