Graves' disease (GD) is an autoimmune disease caused by antibodies to the thyroid stimulating hormone receptor (TSHR). The FDA-cleared Thyretain™ TSI bioassay is a highly specific method to detect thyroid stimulating antibodies (TSAb/TSI) in the blood of patients with autoimmune thyroid disease (AITD), particularly GD. To simplify the workflow of this bioassay and to support a semi-quantitative result, we have generated a stable CHO-K1 cell line expressing both a chimeric TSH receptor (TSHR-Mc4) and a luciferase-based homogeneous cAMP biosensor (GS luciferase). Here, we describe a rapid, real-time, homogenous bioassay (Turbo™ TSI Bioassay) to directly assess the functional activity of TSI and produce results in International Units of IU/L. The Turbo™ TSI bioassay works by measuring changes in the intracellular cAMP level induced by a G-protein coupled receptor (G-PCR) signaling cascade which is triggered by the binding of TSI to the TSHR. Upon binding to cAMP, the GS luciferase reporter is activated through conformational changes and generates light that can be measured in intact cells with a luminometer. The LoD and LoQ of the assay were determined to be 0.016 IU/L and 0.03 IU/L, respectively and the preliminary assay cutoff was determined to be 0.024 IU/L by ROC analysis using the Thyretain™ TSI bioassay results as reference. The analytical performance of the Turbo™ TSI bioassay is comparable to the Thyretain™ TSI bioassay as evidenced by similar EC50 values for a TSHR stimulating monoclonal antibody (M22). The specificity of the Turbo™ TSI bioassay was demonstrated by showing no response to a high concentration of a human monoclonal TSHR blocking antibody (K1-70). The precision of the assay was excellent with an overall within-laboratory precision <15% CV. When testing 198 clinical samples, the positive and negative percent agreement between the Turbo™ TSI and the Thyretain™ TSI bioassays were 98.7% and 93.5%, respectively. While both bioassays yield equivalent analytical and clinical performances, the Turbo™ TSI bioassay is much simpler to perform. It does not require cell culture, sample dilution, washing or cell lysis steps, resulting in a dramatically reduced turnaround time from about 21 h to 60 min. In addition, the same cell line showed its capability of detecting thyroid blocking antibodies (TBAb/TBI) in a competitive format. The Turbo™ TSI bioassay is user-friendly and is a very promising advancement to aid the diagnosis of autoimmune thyroid disease (AITD).
Keywords: Autoimmune thyroid disease; Homogeneous cAMP biosensor; Thyroid blocking immunoglobulins or antibodies; Thyroid stimulating immunoglobulins or antibodies; Thyroid-stimulating hormone receptor.
Copyright © 2021 The Authors. Published by Elsevier B.V. All rights reserved.