Primary Total Knee Arthroplasty Revised for Instability: A Detailed Registry Analysis

J Arthroplasty. 2022 Feb;37(2):286-297. doi: 10.1016/j.arth.2021.11.002. Epub 2021 Nov 9.

Abstract

Background: Instability after total knee arthroplasty is a common but poorly understood complication.

Methods: Data from a large national registry was used to study patient and prosthesis characteristics of 2605 total knee arthroplasty revisions for instability. The cumulative percent revision was calculated using Kaplan-Meier estimates, and Cox proportional models used to compare revision rates. The rate of further revision was analyzed with regard to prostheses used in the first revision.

Results: Instability increased from 6% of all first revision procedures in 2003 to 13% in 2019. The revision risk was lower for minimally stabilized prostheses, males, and patients aged ≥65 years. Polyethylene insert exchange was used for 55% of revision procedures, using a thicker insert in 93% and a change in insert conformity in 24% of cruciate-retaining knees. The increase in either thickness or conformity had no effect on the rate of further revision. After a revision for instability, 24% had a second revision by 14 years. Recurrent instability accounted for 32% of further revisions. A lower second revision rate was seen after revision of both femoral and tibial components, and where constrained components were used.

Conclusion: Revision for instability is increasing. Revising both femoral and tibial components led to a lower rate of second revision compared to a change in insert alone. Recurrent instability was common.

Keywords: arthroplasty; instability; knee; registry; revision.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Arthroplasty, Replacement, Knee* / adverse effects
  • Humans
  • Knee Prosthesis* / adverse effects
  • Male
  • Prosthesis Design
  • Prosthesis Failure
  • Registries
  • Reoperation