Background: Cardiothoracic ratio (CTR) in chest radiographs is still widely used to estimate cardiac size despite the advent of newer imaging techniques. We hypothesise that a universal CTR cut-off value of 50% is a poor indicator of cardiac enlargement. Our aim was to compare CTR with volumetric and functional parameters derived from cardiac magnetic resonance imaging (MRI).
Methods: 309 patients with a chest radiograph and cardiac MRI acquired within a month were reviewed to assess how CTR correlates with multiple cardiac MRI variables: bi-ventricular EDV (absolute and indexed to body surface area), EF, indexed total heart volume and bi-atrial areas. In addition, we have also determined CTR accuracy by creating multiple ROC curves with the described variables.
Results: All cardiac MRI variables correlate weakly but statistically significantly with CTR. This weak correlation is explained by a substantial overlap of cardiac MRI parameters in patients with normal and increased CTR. For all variables, CTR was only mildly to moderately better than a chance to discriminate cardiac enlargement (AUC 0.6-0.7). Large CTR values (> 55%) are specific but not sensitive, while low CTR values (< 45%) are sensitive but not specific. Values in between are not sensitive nor specific.
Conclusions: CTR correlates weakly with true chamber size assessed by gold standard cardiac MRI and has a weak discriminatory power. Thus, clinical decisions based on intermediate CTRs (45-55%) should be avoided. Large CTRs (> 55%) are likely indicative of true heart chamber enlargement. Low CTRs (< 45%) are likely indicative of normal heart size.
Keywords: Cardiac imaging; Cardiac magnetic resonance imaging; Cardiothoracic ratio; Chest radiograph.