AI-Based Quantitative CT Analysis of Temporal Changes According to Disease Severity in COVID-19 Pneumonia

J Comput Assist Tomogr. 2021 Nov-Dec;45(6):970-978. doi: 10.1097/RCT.0000000000001224.

Abstract

Objective: To quantitatively evaluate computed tomography (CT) parameters of coronavirus disease 2019 (COVID-19) pneumonia an artificial intelligence (AI)-based software in different clinical severity groups during the disease course.

Methods: From March 11 to April 15, 2020, 51 patients (age, 18-84 years; 28 men) diagnosed and hospitalized with COVID-19 pneumonia with a total of 116 CT scans were enrolled in the study. Patients were divided into mild (n = 12), moderate (n = 31), and severe (n = 8) groups based on clinical severity. An AI-based quantitative CT analysis, including lung volume, opacity score, opacity volume, percentage of opacity, and mean lung density, was performed in initial and follow-up CTs obtained at different time points. Receiver operating characteristic analysis was performed to find the diagnostic ability of quantitative CT parameters for discriminating severe from nonsevere pneumonia.

Results: In baseline assessment, the severe group had significantly higher opacity score, opacity volume, higher percentage of opacity, and higher mean lung density than the moderate group (all P ≤ 0.001). Through consecutive time points, the severe group had a significant decrease in lung volume (P = 0.006), a significant increase in total opacity score (P = 0.003), and percentage of opacity (P = 0.007). A significant increase in total opacity score was also observed for the mild group (P = 0.011). Residual opacities were observed in all groups. The involvement of more than 4 lobes (sensitivity, 100%; specificity, 65.26%), total opacity score greater than 4 (sensitivity, 100%; specificity, 64.21), total opacity volume greater than 337.4 mL (sensitivity, 80.95%; specificity, 84.21%), percentage of opacity greater than 11% (sensitivity, 80.95%; specificity, 88.42%), total high opacity volume greater than 10.5 mL (sensitivity, 95.24%; specificity, 66.32%), percentage of high opacity greater than 0.8% (sensitivity, 85.71%; specificity, 80.00%) and mean lung density HU greater than -705 HU (sensitivity, 57.14%; specificity, 90.53%) were related to severe pneumonia.

Conclusions: An AI-based quantitative CT analysis is an objective tool in demonstrating disease severity and can also assist the clinician in follow-up by providing information about the disease course and prognosis according to different clinical severity groups.

Publication types

  • Evaluation Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Artificial Intelligence*
  • COVID-19 / diagnostic imaging*
  • Evaluation Studies as Topic
  • Female
  • Humans
  • Lung / diagnostic imaging*
  • Male
  • Middle Aged
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Reproducibility of Results
  • Retrospective Studies
  • SARS-CoV-2
  • Sensitivity and Specificity
  • Severity of Illness Index
  • Time
  • Tomography, X-Ray Computed / methods*
  • Young Adult