Objective: To compare the new zero-profile (Zero-P) fusion cage with regular cage and plate (CP) in the treatment of anterior cervical single-level cervical degenerative diseases.
Methods: Patients operated from January 2013 to August 2018 were enrolled. They were divided into the Zero-P group (n = 74 cases) and CP groups (n = 116 cases). Follow-up assessment was at 1, 3, 12, and 24 months after surgery, including the incidence of dysphagia, visual analogue scale (VAS) score, Japanese orthopaedic association (JOA)score, C2-C7 Cobb angle, intervertebral disc height (IDH) and adjacent joint degeneration.
Results: The operation time and blood loss of patients in Zero-P group were less than those in the CP group, and there was no difference in hospitalization time. All 190 patients were followed up for 24 to 72 months, with an average of 35.29 months. In terms of clinical outcomes, vas and JOA scores of the two groups were significantly improved at one month and the last follow-up. The incidence of dysphagia in the Zero-P group was lower than that in the CP group. On radiological effects, Cobb angle and IDH showed significant correction in both groups, but the degeneration rate of adjacent joints in the Zero-P group was lower than the CP group.
Conclusions: In ACDF, the clinical and radiological results of Zero-P and CP devices are satisfactory, but Zero-P cage may be superior in operation time, blood loss, the incidence of dysphagia and adjacent joint degeneration.
Keywords: Cervical spondylosis; anterior cervical decompression and fusion; cage plate; zero-profile.