Abstract

Background: Intra-operative fluoroscopy has been shown to improve the accuracy of acetabular component positioning when compared to no fluoroscopy in direct anterior approach (DAA) total hip arthroplasty (THA). Due to logistical reasons, our senior author has been performing DAA THA at one institution without the use of fluoroscopy and has created an intraoperative referencing technique to aid in acetabular component positioning. The purpose of this study is to evaluate the accuracy of acetabular component positioning using fluoroscopy when compared to an intra-operative referencing technique without fluoroscopy.

Methods: A total of 214 consecutive primary DAA THA were performed by one surgeon at two institutions and were retrospectively reviewed over a 3-year period. Intra-operative fluoroscopy was used with all patients at Institution A (N = 154). At institution B (N = 60), no fluoroscopy was used, and an intra-operative referencing technique was employed to assist in placement of the acetabular component.

Results: In the fluoroscopy group, 91% of components met our abduction target, 90% met our anteversion target, and 82.5% simultaneously met both targets. In the non-fluoroscopy group, 98% of components met our abduction target, 92% met our anteversion target, and 90% simultaneously met both targets. There was no difference between groups for placement of the component within both targets simultaneously (p = .171).

Conclusion: Use of our intra-operative referencing technique is non-inferior in placing acetabular components within a pre-defined safe zone when compared to use of intraoperative fluoroscopy. The intra-operative reference technique can be a helpful adjunct for ensuring accurate acetabular component positioning while simultaneously reducing cost and limiting radiation exposure.

Keywords: Acetabular component positioning; Direct anterior approach; Fluoroscopy; Total hip arthroplasty.