A simple, rapid, and sensitive LC-MS/MS method for determining concentrations of the anticancer alkaloid vincristine in micro volumes of mouse plasma was developed and validated in positive ion mode. Separation of vincristine and the internal standard [2H3]-vincristine was achieved on an Accucore aQ column with a gradient mobile phase delivered at a flow rate of 0.4 mL/min and a run time of 2.2 min. Calibration curves were linear (r2 > 0.99, n = 8) up to 250 ng/mL, with a lower limit of quantitation of 2.5 ng/mL. The matrix effect and extraction recovery for vincristine were ranging 108-110% and 88.4-107%, respectively. The intra-day and inter-day precision of quality controls tested at 3 different concentrations were always less than 15%, and accuracy ranged from 91.7 to 107%. The method was successfully applied to evaluate the pharmacokinetic profile of vincristine in wild-type and CYP3A-deficient mice in support of a project to provide mechanistic insight into drug-drug interactions and to identify sources of inter-individual pharmacokinetic variability associated with vincristine-induced peripheral neuropathy.
Keywords: Mouse plasma; Pharmacokinetics; UHPLC-MS/MS; Vincristine.
Copyright © 2021 The Author(s). Published by Elsevier B.V. All rights reserved.