Increasing SARS-CoV-2 RT-qPCR testing capacity by sample pooling

Int J Infect Dis. 2021 Feb:103:19-22. doi: 10.1016/j.ijid.2020.11.155. Epub 2020 Nov 19.

Abstract

Objectives: Limited testing capacity has characterized the ongoing coronavirus disease 2019 (COVID-19) pandemic in Spain, hampering timely control of outbreaks and opportunities to reduce the escalation of community transmission. This study investigated the potential to use sample pooling, followed by one-step retrotranscription and real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) to increase testing capacity for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2).

Methods: Various pool sizes (five, 10 and 15 samples) were evaluated prior to RNA extraction followed by standard RT-qPCR for the diagnosis of COVID-19. The pool size achieving reproducible results with individual sample testing was subsequently used to assess nasopharyngeal samples in a tertiary hospital in August 2020.

Results: A pool size of five samples had higher sensitivity compared with pool sizes of 10 and 15 samples, showing a mean cycle threshold (Ct) shift of 3.5 [standard deviation (SD) 2.2] between the pooled test and positive samples in the pool. Next, a pool size of five was used to test a total of 895 pools (4475 prospective samples) using two different RT-qPCR kits. The Real Accurate Quadruplex corona-plus PCR Kit (PathoFinder) reported the lowest mean Ct shift [2.2 (SD 2.4)] between the pool and individual samples. This strategy enables detection of individual positive samples in positive pools with Ct of 16.7-39.4.

Conclusions: Grouping samples into pools of five for RT-qPCR resulted in an increase in SARS-CoV-2 testing capacity with minimal loss of sensitivity compared with testing each sample individually.

Keywords: COVID-19; SARS-CoV-2; Sample pooling; Scalability; Testing capacity.

MeSH terms

  • COVID-19 / diagnosis*
  • COVID-19 Testing*
  • Humans
  • Nasopharynx / virology
  • Prospective Studies
  • Reagent Kits, Diagnostic
  • Real-Time Polymerase Chain Reaction / methods*
  • Reverse Transcriptase Polymerase Chain Reaction / methods*
  • SARS-CoV-2*
  • Sensitivity and Specificity

Substances

  • Reagent Kits, Diagnostic