Mid-Term Results of Endovascular Aneurysm Sealing in the Treatment of Abdominal Aortic Aneurysm With Unfavorable Morphology

Vasc Endovascular Surg. 2021 Jan;55(1):39-49. doi: 10.1177/1538574420965736. Epub 2020 Oct 9.

Abstract

Purpose: To report mid-term results of endovascular aneurysm sealing (EVAS) of abdominal aortic aneurysms (AAA) deemed unsuitable for a standard endovascular aneurysm repair (EVAR).

Methods: A prospectively maintained database of 42 patients with EVAR-unfavorable anatomy treated by EVAS combined with chimney grafts in case of the proximal AAA neck shorter than 5 mm was analyzed. Early outcomes included final angiographic result, intra- and early post-operative deaths, and complications. Mid-term outcomes included all-cause mortality (ACM), aneurysm-related mortality (ARM), patency of the stents, occurrence of endoleaks, serious complications and graft failures defined as the AAA growth of more than 5 mm, type I endoleak, occlusion of the stent-graft or chimney graft, aorto-duodenal fistula, or aneurysm rupture.

Results: The procedure was completed in all patients. Twenty-eight chimney grafts were implanted in 19 patients. Patients were followed for a median of 24 months (range 12-34 months). There were 2 intraoperative ruptures and 1 patient died in an early postoperative period. The cumulative ACM was 15, 21, and 36% at 12, 24, and 36 months, respectively, and the cumulative ARM was 8, 11, and 27% at 12, 24, and 36 months, respectively. Three out of 5 aneurysm-related deaths were due to a secondary aorto-duodenal fistula. The cumulative incidence of graft failure was 20, 27, and 42% at 12, 24, and 36 months, respectively. The cumulative incidence of an endoleak was 5, 9, and 23% at 12, 24, and 36 months, respectively. The graft failure increased significantly both ACM (p = .012) and ARM (p = .00003). The implantation of chimney grafts at the initial procedure increased ARM significantly (p = .008). The presence of an endoleak did not have any significant influence on ACM and ARM.

Conclusion: Patients treated with EVAS for AAAs with EVAR-unfavorable anatomy, especially those with chimney grafts, exhibit a high risk of graft failure and subsequent death.

Keywords: Nellix device; abdominal aortic aneurysm; chimney grafts; endovascular aneurysm sealing; outside IFU.

MeSH terms

  • Aged
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / mortality
  • Aortic Aneurysm, Abdominal / therapy*
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Blood Vessel Prosthesis Implantation* / mortality
  • Databases, Factual
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / instrumentation
  • Endovascular Procedures* / mortality
  • Female
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / mortality
  • Postoperative Complications / therapy
  • Prosthesis Failure
  • Risk Assessment
  • Risk Factors
  • Stents
  • Time Factors
  • Treatment Outcome