Impact of Fast-Acting Insulin Aspart on Glycemic Control in Patients with Type 1 Diabetes Using Intermittent-Scanning Continuous Glucose Monitoring Within a Real-World Setting: The GoBolus Study

Diabetes Technol Ther. 2021 Mar;23(3):203-212. doi: 10.1089/dia.2020.0360. Epub 2020 Oct 21.

Abstract

Background: The GoBolus study investigated the real-world effectiveness of faster aspart in patients with type 1 diabetes (T1D) using intermittent-scanning continuous glucose monitoring (iscCGM) systems. Methods: This 24-week, multicenter, single-arm, noninterventional study investigated adults with T1D (HbA1c, 7.5%-9.5%) receiving multiple daily injections (MDI) of insulin and using iscCGM within local healthcare settings for ≥6 months before switching to faster aspart at study start (week 0; baseline). Primary endpoint was HbA1c change from baseline to week 24. Exploratory endpoint was change in iscCGM metrics from baseline to week 24. Results: Overall, 243 patients were included (55.6% male), with mean age/diabetes duration, 49.9/18.8 years; mean HbA1c, 8.1%. By week 24, HbA1c had decreased by 0.19% (-2.1 mmol/mol, P < 0.0001) with no mean change in insulin doses or basal/bolus insulin ratios. For patients with sufficient available iscCGM data (n = 92): "time in range" (TIR; 3.9-10.0 mmol/L) increased from 46.9% to 50.1% (P = 0.01), corresponding to an increase of 46.1 min/day; time in hyperglycemia decreased from 49.1% to 46.1% (>10.0 mmol/L, P = 0.026) and 20.4% to 17.9% (>13.9 mmol/L, P = 0.013), corresponding to 43.5 (P = 0.024) and 35.6 (P = 0.015) fewer minutes per day on average spent in these ranges, respectively; no change for time in hypoglycemia (<3.9 and <3.0 mmol/L). Mean interstitial and postprandial glucose improved from 10.4 to 10.1 mmol/L (P = 0.035) and 11.9 to 11.0 mmol/L (P = 0.002), respectively. Conclusion: Real-world switching to faster aspart in adults with T1D on MDI improved HbA1c, increased TIR, and decreased time in hyperglycemia without affecting time in hypoglycemia. The GoBolus study: NCT03450863.

Keywords: Continuous glucose monitoring; Diabetes mellitus; Prandial insulin; Time-in-range.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Blood Glucose
  • Blood Glucose Self-Monitoring
  • Diabetes Mellitus, Type 1* / drug therapy
  • Female
  • Glycated Hemoglobin / analysis
  • Glycemic Control
  • Humans
  • Hypoglycemic Agents / therapeutic use
  • Insulin / therapeutic use
  • Insulin Aspart* / therapeutic use
  • Male
  • Middle Aged

Substances

  • Blood Glucose
  • Glycated Hemoglobin A
  • Hypoglycemic Agents
  • Insulin
  • Insulin Aspart

Associated data

  • ClinicalTrials.gov/NCT03450863