Background: Most studies comparing the efficacy of hypothermic machine perfusion (HMP) versus static cold storage (SCS) are based on short-term outcomes. We aimed to better evaluate the mid-term impact of HMP in patients receiving expanded criteria donor (ECD) kidneys.
Methods: The analyses were based on the French Données Informatisées et VAlidées en Transplantation (DIVAT) observational cohort. Patients aged ≥45 years transplanted for the first or second times from an ECD donor since 2010 were studied. Our study reported the graft and/or patient survivals and the incidence of acute rejection episode. The Cox models and the Kaplan-Meier estimators, weighted on the propensity score, were used to study the times-to-events.
Results: Among the 2019 included patients, 1073 were in the SCS group versus 946 in the HMP group. The mean life expectancy with functioning graft was 5.7 years [95% confidence interval (CI) 5.4-6.1] for the HMP cohort followed-up for 8 years post-transplantation versus 6.0 years (95% CI 5.7-6.2) for the SCS group. These mid-term results were comparable in the patients receiving grafts from donors aged ≥70 years and in the transplantations with cold ischaemia time ≥18 h.
Conclusions: Our study challenges the utility of using HMP to improve mid-term patient and graft survival. Nevertheless, the improvement of the short-term outcomes is indisputable. It is necessary to continue technological innovations to obtain long-term results.
Keywords: cohort; kidney transplantation; machine perfusion; marginal grafts; mid-term outcomes.
© The Author(s) 2019. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.