Introduction of Group Electronic Monitoring of Hand Hygiene on Inpatient Units: A Multicenter Cluster Randomized Quality Improvement Study

Clin Infect Dis. 2020 Dec 17;71(10):e680-e685. doi: 10.1093/cid/ciaa412.

Abstract

Background: The current approach to measuring hand hygiene (HH) relies on human auditors who capture <1% of HH opportunities and rapidly become recognized by staff, resulting in inflation in performance. Group electronic monitoring is a validated method of measuring HH adherence, but data demonstrating the clinical impact of this technology are lacking.

Methods: A stepped-wedge cluster randomized quality improvement study was performed on 26 inpatient medical and surgical units across 5 acute care hospitals in Ontario, Canada. The intervention involved daily HH reporting as measured by group electronic monitoring to guide unit-led improvement strategies. The primary outcome was monthly HH adherence (percentage) between baseline and intervention. Secondary outcomes included transmission of antibiotic-resistant organisms such as methicillin-resistant Staphylococcus aureus (MRSA) and other healthcare-associated infections.

Results: After adjusting for the correlation within inpatient units and hospitals, there was a significant overall improvement in HH adherence associated with the intervention (incidence rate ratio [IRR], 1.73 [95% confidence interval {CI}, 1.47-1.99]; P < .0001). Monthly HH adherence relative to the intervention increased from 29% (1 395 450/4 544 144) to 37% (598 035/1 536 643) within 1 month, followed by consecutive incremental increases up to 53% (804 108/1 515 537) by 10 months (P < .0001). There was a trend toward reduced healthcare-associated transmission of MRSA (IRR, 0.74 [95% CI, .53-1.04]; P = .08).

Conclusions: The introduction of a system for group electronic monitoring led to rapid, significant improvements in HH performance within a 2-year period. This method offers significant advantages over direct observation for measurement and improvement of HH.

Keywords: electronic monitoring; hand hygiene; healthcare-associated infection; nosocomial infection; quality improvement.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cross Infection* / prevention & control
  • Electronics
  • Guideline Adherence
  • Hand Disinfection
  • Hand Hygiene*
  • Humans
  • Infection Control
  • Inpatients
  • Methicillin-Resistant Staphylococcus aureus*
  • Ontario
  • Quality Improvement