Complex high-risk and indicated percutaneous coronary intervention for stable angina: Does operator volume influence patient outcome?

Am Heart J. 2020 Apr:222:15-25. doi: 10.1016/j.ahj.2019.12.019. Epub 2020 Jan 7.

Abstract

Background: Complex high-risk and indicated revascularization using percutaneous coronary intervention (CHIP-PCI) is an emerging concept that is poorly studied.

Objective: To define temporal changes in CHIP-PCI volumes, and the relationship between operator CHIP-PCI volume and patient outcomes.

Methods and results: Data were analyzed on all CHIP-PCI procedures undertaken for stable angina in England and Wales between 2007 and 2014. Operator volume data was available for 2012-14. CHIP-PCI was defined by patient characteristics (age ≥80years, left ventricular (LV) ejection fraction <30%, previous CABG, or chronic renal failure) and/or by procedural characteristics (left main PCI, chronic total occlusion PCI, LV support, use of rotational atherectomy or laser atherectomy). CHIP-PCI as a percentage of total PCI increased from 28.1% in 2007 to 36.2% in 2014 (P < .001). Between 2012 and 2014, a total of 30,268 CHIP-PCI cases were performed. Total operator volume varied from 1 to 580 cases with median total operator volume of 29 cases. Higher operator volumes were associated with a greater degree of patient comorbidity and increasing procedural complexity. After adjustment for baseline difference, in-hospital major bleeding (P < .001 for trend), access site complications (P < .001) and coronary perforation (P = .002) were associated with increasing operator CHIP-PCI volumes. However, the frequency of in-hospital death (P = .394) and 12-month mortality (P = .638) were similar across the volume quartiles. Higher volumes quartiles were associated with a greater likelihood of same day discharge (P < .001).

Conclusions: CHIP-PCI cases are an increasingly large population in contemporary PCI practice. Higher operator volumes were not associated with improved 12-month survival.

Condensed abstract: Data were analyzed on all complex high-risk and indicated revascularization using percutaneous coronary intervention (CHIP-PCI) procedures in England and Wales between 2007 and 2014. CHIP-PCI as a percentage of total PCI increased from 28.1% in 2007 to 36.2% in 2014 (P < .001). Median total operator volume was 29 cases with higher volumes associated with more patient comorbidity and increasing procedural complexity. In-hospital major bleeding (P < .001 for trend), access site complications (P < .001) and coronary perforation (P = .002) all associated with increasing operator CHIP-PCI volumes. However, trends for in-hospital death (P = .394), and 12-month mortality (P = .638) were similar across the volume quartiles.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Angina, Stable / mortality
  • Angina, Stable / surgery*
  • Databases, Factual
  • England / epidemiology
  • Female
  • Follow-Up Studies
  • Hospital Mortality / trends
  • Humans
  • Male
  • Percutaneous Coronary Intervention / statistics & numerical data*
  • Registries*
  • Retrospective Studies
  • Risk Assessment / methods*
  • Risk Factors
  • Survival Rate / trends
  • Treatment Outcome
  • Wales / epidemiology
  • Workload / statistics & numerical data*