Abstract

CT angiography with multislice detector has become the preferred method for assessment of hemodynamically stable patients suspected of great vessel injury from iatrogenic and blunt trauma. The CT images obtained can be transformed into a three-dimensional (3D) model using the software within minutes. This allows the clinician to evaluate the injury and the injury's proximity to other vital structures for operative planning. The 3D modeling provides geometric calibration of the c-arm or image intensifier in regard to optimal cranial/caudal and oblique angles to evaluate and treat the vessel injury. We describe a case of a 28-year-old female undergoing a cesarian section and hysterectomy for placenta percreta, who sustained a right subclavian artery injury (presumed wire injury) from inadvertent right common carotid artery cannulation during placement of a right internal jugular 8 French resuscitative central line. A 3D model was created from the CT angiography to locate the small pseudoaneurysm of the right subclavian artery. The optimal projection was obtained using the 3D reconstructive software to visualize the injury and its relation to the right vertebral artery ostium for endovascular planning. This preoperative maneuver allowed for limited radiation exposure and contrast volume used to treat the injury.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Catheterization, Central Venous / adverse effects
  • Computed Tomography Angiography* / adverse effects
  • Contrast Media / administration & dosage*
  • Contrast Media / adverse effects
  • Endovascular Procedures* / adverse effects
  • Female
  • Fluoroscopy
  • Humans
  • Iatrogenic Disease*
  • Imaging, Three-Dimensional* / adverse effects
  • Multidetector Computed Tomography* / adverse effects
  • Patient-Specific Modeling*
  • Predictive Value of Tests
  • Pregnancy
  • Radiation Dosage
  • Radiation Exposure / adverse effects
  • Radiation Exposure / prevention & control
  • Radiography, Interventional* / adverse effects
  • Subclavian Artery / diagnostic imaging*
  • Subclavian Artery / injuries
  • Subclavian Artery / physiopathology
  • Subclavian Artery / surgery*
  • Surgery, Computer-Assisted* / adverse effects
  • Time Factors
  • Treatment Outcome
  • Vascular System Injuries / diagnostic imaging*
  • Vascular System Injuries / etiology
  • Vascular System Injuries / physiopathology
  • Vascular System Injuries / surgery*

Substances

  • Contrast Media