Background: Little is known about the impact of frailty on length of stay (LOS), cost, and in-hospital procedural outcomes of cardiac implantable electronic device (CIED) implantation procedures.
Methods: All de novo CIED implantations recorded in the United States (2004-2014) from a national database were stratified according to the Hospital Frailty Risk Score into low-risk (LRF; <5), intermediate-risk (IRF; 5-15), and high-risk (HRF; > 15) frailty groups. Regression analyses were performed to assess the association between frailty and procedural outcomes.
Results: Of 2,902,721 implantations, LRF, IRF, and HRF were 77.6%, 21.2%, and 1.2%, respectively. Frailty increased from 2004 to 2014 (IRF: 14.3% to 32.5%, HRF: 0.2% to 3.3%). Complications were 2- to 3-fold higher in the IRF and HRF groups, whereas all-cause mortality was 4- to 9-fold higher in the IRF (2.9%) and HRF (5.3%) groups, depending on the type of CIED (P < 0.001 for all). Rates of complications increased over the study years and all-cause mortality declined, especially in the higher frailty risk groups (2004 vs 2014; mortality: IRF: 3.8% vs 2.2%, HRF: 9.9% vs 4.5%; bleeding: IRF: 3.7% vs 9.0%, HRF: 3.9% vs 12.2%; thoracic: IRF: 4.3% vs 6.0%, HRF: 2.9% vs 9.1%; cardiac: IRF: 0.5% vs 0.9%, HRF: 0.5% vs 0.9%). Rising frailty was associated with an increase in cost (P < 0.001) and LOS (median 3, 8, 11 days for LRF, IRF, HRF, respectively, P < 0.001). The cost for patients with HRF receiving a defibrillator was approximately a quarter million USD$ per patient.
Conclusions: Frailty is associated with worse clinical outcomes, higher cost, and LOS independent of age or CIED type. Our findings emphasize the importance of frailty assessment.
Copyright © 2019 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.