Three-dimensional mean CT attenuation value of pure and part-solid ground-glass lung nodules may predict invasiveness in early adenocarcinoma

Clin Radiol. 2019 Dec;74(12):944-949. doi: 10.1016/j.crad.2019.09.130. Epub 2019 Oct 18.

Abstract

Aim: This study evaluated the relationship between three-dimensional (3D) mean computed tomography (CT) attenuation values of ground-glass nodules (GGN) and pathological invasiveness in early lung adenocarcinoma. The diagnostic accuracy of 3D CT attenuation values was compared with that of two-dimensional (2D) CT attenuation values and standardised uptake value on positron-emission tomography (PET).

Materials and methods: Surgical and radiological data from 96 pure or part-solid GGNs of <20 mm were analysed retrospectively. Mean 2D and 3D CT attenuation values of the tumours were obtained with semi-automated volumetric software. Pathological invasiveness was diagnosed according to the International Association for the Study of Lung Cancer (IASLC))/American Thoracic Society (ATS)/European Respiratory Society (ERS) classification. Pre-invasive lesions and minimally invasive adenocarcinomas were classified as non-invasive adenocarcinoma. Univariate and multivariate analyses determined relationships between pathological invasiveness and clinical/radiological findings. Receiver operating characteristic (ROC) analysis was performed to determine the optimal cut-off value for detecting invasive adenocarcinoma.

Results: A total of 66 non-invasive and 30 invasive adenocarcinoma cases between 2010 and 2016 were analysed. Univariate analysis revealed four tumour invasiveness-associated predictors: maximum diameter, SUVmax, mean 2D CT attenuation value, and mean 3D CT attenuation value (p<0.05). Multivariate analysis revealed that the maximum diameter, SUVmax, and mean 3D CT attenuation value were significant predictors of pathological invasiveness (p=0.023, 0.022, 0.004). The area under the ROC curve to predict invasive adenocarcinoma for mean 3D CT attenuation value was 0.838 and the cut-off value was -489 HU.

Conclusion: The mean 3D CT attenuation value could distinguish pre-invasive lesions and minimally invasive adenocarcinoma from invasive adenocarcinoma.

MeSH terms

  • Adenocarcinoma / diagnosis
  • Adenocarcinoma / diagnostic imaging*
  • Adenocarcinoma / pathology
  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Humans
  • Imaging, Three-Dimensional
  • Lung / diagnostic imaging
  • Lung / pathology
  • Lung Neoplasms / diagnosis
  • Lung Neoplasms / diagnostic imaging*
  • Lung Neoplasms / pathology
  • Male
  • Middle Aged
  • Neoplasm Invasiveness / diagnostic imaging
  • Retrospective Studies
  • Solitary Pulmonary Nodule / diagnosis
  • Solitary Pulmonary Nodule / diagnostic imaging*
  • Solitary Pulmonary Nodule / pathology
  • Tomography, X-Ray Computed / methods*