Balloon-expandable transcatheter aortic valve replacement outcomes by procedure location: Catheterization laboratory versus operating room

Cardiovasc Revasc Med. 2020 Feb;21(2):149-154. doi: 10.1016/j.carrev.2019.04.007. Epub 2019 Apr 30.

Abstract

Background: The impact of procedure location on clinical outcomes after TAVR remains unclear. We aimed to compare short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) in the catheterization laboratory (CATH) versus surgical operating room (OR).

Methods: A retrospective review of 63,581 trans-femoral TAVR patients using balloon-expandable valves from 2015 to 2018 were captured utilizing the TVT Registry. Propensity score matching was performed using 24 covariates resulting in 2 risk-adjusted groups. Patients were further stratified by STS Risk Score with outcomes compared.

Results: Propensity score matching resulted in 24,160 risk-matched CATH and OR patient pairs. Short-term clinical outcomes including all-cause mortality, stroke, major vascular complications, life-threatening bleeding, and new dialysis were similar between CATH and OR (p = all ns). There was no difference in conversion to open heart surgery between CATH and OR with both occurring at a very low rate (0.4% vs. 0.5%, p = 0.07). Moreover, the 30-day survival post-conversion was similar whether TAVR was performed in CATH versus OR (43.3% and 49.7%, p = 0.28). When stratified by STS Risk Score, there was no difference in conversion to surgery or 30-day mortality in low and intermediate risk patients between CATH and OR. For high risk patients, however, conversion to surgery was lower in CATH vs. OR (0.2% vs. 0.4%, p = 0.04) with no difference in 30-day survival (46% vs. 43%, p = 0.94).

Conclusions: Procedure location has minimal impact on TAVR procedural and 30-day outcomes with a very low conversion to open surgery rate between CATH versus OR for low, intermediate, and high-risk patients.

Keywords: Catheterization laboratory; Conversion to open surgery; Hybrid operating room; STS risk score; Transcatheter aortic valve replacement.

Publication types

  • Comparative Study
  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Balloon Valvuloplasty* / adverse effects
  • Balloon Valvuloplasty* / mortality
  • Cardiac Catheterization* / adverse effects
  • Cardiac Catheterization* / instrumentation
  • Cardiac Catheterization* / mortality
  • Conversion to Open Surgery
  • Female
  • Heart Valve Prosthesis
  • Humans
  • Laboratories, Hospital*
  • Male
  • Operating Rooms*
  • Postoperative Complications / mortality
  • Postoperative Complications / therapy
  • Prosthesis Design
  • Registries
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Transcatheter Aortic Valve Replacement* / instrumentation
  • Transcatheter Aortic Valve Replacement* / mortality
  • Treatment Outcome
  • United States