Cardiac resynchronization therapy non-responder to responder conversion rate in the more response to cardiac resynchronization therapy with MultiPoint Pacing (MORE-CRT MPP) study: results from Phase I

Eur Heart J. 2019 Sep 14;40(35):2979-2987. doi: 10.1093/eurheartj/ehz109.

Abstract

Aims: To assess the impact of MultiPoint™ Pacing (MPP)-programmed according to the physician's discretion-in non-responders to standard biventricular pacing after 6 months.

Methods and results: The study enrolled 1921 patients receiving a quadripolar cardiac resynchronization therapy (CRT) system capable of MPP™ therapy. A core laboratory assessed echocardiography at baseline and 6 months and defined volumetric non-response to biventricular pacing as <15% reduction in left ventricular end-systolic volume (LVESV). Clinical sites randomized patients classified as non-responders in a 1:1 ratio to receive MPP (236 patients) or continued biventricular pacing (231 patients) for an additional 6 months and evaluated rate of conversion to echocardiographic response. Baseline characteristics of both groups were comparable. No difference was observed in non-responder to responder conversion rate between MPP and biventricular pacing (31.8% and 33.8%, P = 0.72). In the MPP arm, 68 (29%) patients received MPP programmed with a wide LV electrode anatomical separation (≥30 mm) and shortest LV1-LV2 and LV2-RV timing delays (MPP-AS); 168 (71%) patients received MPP programmed with other settings (MPP-Other). MPP-AS elicited a significantly higher non-responder conversion rate compared to MPP-Other (45.6% vs. 26.2%, P = 0.006) and a trend in a higher conversion rate compared to biventricular pacing (45.6% vs. 33.8%, P = 0.10).

Conclusions: After 6 months, investigator-discretionary MPP programming did not significantly increase echocardiographic response compared to biventricular pacing in CRT non-responders.

Trial registration: ClinicalTrials.gov NCT02006069.

Keywords: Biventricular pacing; Cardiac resynchronization; Heart failure; MPP; MultiPoint Pacing; Quadripolar left ventricular pacing; Randomized controlled study.

Publication types

  • Clinical Trial, Phase I
  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cardiac Pacing, Artificial / methods*
  • Cardiac Resynchronization Therapy / methods*
  • Cardiac Resynchronization Therapy Devices*
  • Double-Blind Method
  • Echocardiography
  • Electrocardiography
  • Female
  • Follow-Up Studies
  • Heart Failure / diagnostic imaging
  • Heart Failure / physiopathology
  • Heart Failure / therapy*
  • Hemodynamics / physiology
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Surveys and Questionnaires*
  • Treatment Outcome

Associated data

  • ClinicalTrials.gov/NCT02006069