Arterial blood sampling in male CD-1 and C57BL/6J mice with 1% isoflurane is similar to awake mice

J Appl Physiol (1985). 2018 Dec 1;125(6):1749-1759. doi: 10.1152/japplphysiol.00640.2018. Epub 2018 Oct 4.

Abstract

Isoflurane (ISO) is a commonly used anesthetic that offers rapid recovery for laboratory animal research. Initial studies indicated no difference in arterial Pco2 ( PaCO2 ) or pH between conscious (NO ISO) and 1% ISO-exposed CD-1 mice. Our laboratory investigated whether arterial blood sampling with 1% ISO is a suitable alternative to NO ISO sampling for monitoring ventilation in a commonly studied mouse strain. We hypothesized similar blood chemistry, breathing patterns, and cardiovascular responses with NO ISO and 1% ISO. C57BL/6J mice underwent unrestrained barometric plethysmography to quantify the pattern of breathing. Mice exposed to hypoxic and hypercapnic gas under 1% ISO displayed blunted responses; with air, there were no breathing differences. Blood pressure and heart rate were not different between NO ISO and 1% ISO-exposed mice breathing air. Oxygen saturation was not different between groups receiving 2% ISO, 1% ISO, or air. Breathing frequency stabilized at ~11 min of 1% ISO following 2% ISO exposure, suggesting that 11 min is the optimal time for a sample in C57BL/6J mice. Blood samples at 1% ISO and NO ISO revealed no differences in blood pH and PaCO2 in C57BL/6J mice. Overall, this method reveals similar arterial blood sampling values in awake and 1% ISO CD-1 and C57BL/6J mice exposed to air. Although this protocol may be appropriate in other mouse strains when a conscious sample is not feasible, caution is warranted first to identify breathing frequency responses at 1% ISO to tailor the protocol. NEW & NOTEWORTHY Conscious arterial blood sampling is influenced by extraneous factors and is a challenging method due to the small size of mice. Through a series of experiments, we show that arterial blood sampling with 1% isoflurane (ISO) is an alternative to awake sampling in C57BL/6J and CD-1 male mice breathing air. Monitoring breathing frequency during 1% ISO is important to the protocol and should be closely followed to confirm adequate recovery after the catheter implantation.

Keywords: Pa; pH; pulse oximetry.

Publication types

  • Evaluation Study
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anesthetics, Inhalation*
  • Animals
  • Blood Pressure
  • Blood Specimen Collection / methods*
  • Femoral Artery / surgery*
  • Heart Rate
  • Isoflurane*
  • Male
  • Mice, Inbred C57BL
  • Oximetry
  • Respiration
  • Wakefulness*

Substances

  • Anesthetics, Inhalation
  • Isoflurane