Intravoxel incoherent motion diffusion-weighted imaging for the assessment of renal fibrosis of chronic kidney disease: A preliminary study

Magn Reson Imaging. 2018 Apr:47:118-124. doi: 10.1016/j.mri.2017.12.010. Epub 2017 Dec 5.

Abstract

Purpose: To investigate the potential of Intravoxel incoherent motion diffusion-weighted imaging(IVIM-DWI) for the assessment of renal fibrosis in chronic kidney disease (CKD), using histopathology as a reference standard.

Methods: Eighty-five CKD patients and twenty healthy volunteers were recruited in this study. IVIM-DWI was performed in all of the participants, and all of the CKD patients underwent renal biopsy. The mean values of the true diffusion coefficient (D), pseudo diffusion coefficient (D*) and perfusion fraction (f) in the renal cortex and medulla were compared between the CKD patients and healthy volunteers. The Spearman correlation coefficient was calculated to assess the relationship between the D, D*,f values and the estimated glomerular filtration rate (eGFR), serum creatinine level (SCr), 24h urinary protein level (24h-UPRO), histopathological fibrosis scores.

Results: The D, D* and f values were significantly lower in medulla than in the cortex for all of the participants. All of the IVIM parameters were significantly lower in the CKD patients than in the healthy controls. In the CKD patients, a significant negative correlation was found between the renal parenchymal D, D*,f values and the 24h-UPRO, as well as between the renal parenchymal D, f values and the SCr. There was a significant positive correlation between all of the IVIM parameters and the eGFR. All of the IVIM parameters exhibited a significant negative correlation with the histopathological fibrosis score.

Conclusion: IVIM-DWI shows great potential in the noninvasive assessment of renal fibrosis in CKD.

Keywords: Chronic kidney disease; Intravoxel incoherent motion diffusion-weighted imaging; Magnetic resonance imaging; Renal fibrosis.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Diffusion Magnetic Resonance Imaging*
  • Female
  • Fibrosis / diagnostic imaging*
  • Glomerular Filtration Rate
  • Healthy Volunteers
  • Humans
  • Image Processing, Computer-Assisted
  • Kidney / diagnostic imaging
  • Male
  • Middle Aged
  • Motion
  • Perfusion
  • Prospective Studies
  • Reference Standards
  • Renal Insufficiency, Chronic / diagnostic imaging*