Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry

Interact Cardiovasc Thorac Surg. 2017 Nov 1;25(5):757-764. doi: 10.1093/icvts/ivx159.

Abstract

Objectives: Transaortic (TAo) access for transcatheter aortic valve implantation (TAVI) is an alternative to the conventional transfemoral or transapical routes. Data comparing the characteristics and outcomes of TAo-TAVI using the SAPIEN XT and SAPIEN 3 heart valves are scarce. The objective of the current analysis was to provide such information.

Methods: ROUTE is an international, prospective, observational registry. Patients with severe calcific aortic stenosis scheduled for TAo-TAVI with an Edwards SAPIEN XT or a SAPIEN 3 heart valve were consecutively enrolled at 22 centres across Europe between February 2013 and February 2015. Periprocedural, in-hospital and 30-day complication rates were assessed.

Results: Of the 301 patients included, 126 (41.9%) received a SAPIEN 3 and 175 (58.1%) a SAPIEN XT. The SAPIEN 3 was associated with shorter procedure time (101 ± 35 vs 111 ± 40 min; P = 0.031) and a lower quantity of contrast agent used (87 ± 43 vs 112 ± 50 ml; P < 0.001). Balloon dilation was performed less often before (68.0% vs 78.3%; P = 0.045) and after implantation (13.6% vs 30.1%; P = 0.001). No statistically significant differences between the valve types were documented for overall (4.1% SAPIEN 3 vs 7.6% SAPIEN XT; P = 0.21), TAVI-related (0.8% vs 4.7%; P = 0.084) and cardiovascular mortality (2.4% vs 5.9%; P = 0.158). Major vascular complications were less frequent (0.8% vs 5.3%; P = 0.049), and there was a lower rate of moderate-to-severe paravalvular regurgitation (0.8% vs 5.1%; P = 0.050) in the SAPIEN 3 group.

Conclusions: Both the SAPIEN XT and SAPIEN 3 were safely implanted via the TAo route, though the SAPIEN 3 may be associated with a higher procedural success rate and improved prognosis.

Clinicaltrials.gov identifier: NCT01991431.

Keywords: Balloon expandable; Mortality; Transaortic; Transcatheter aortic valve implantation.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Aged, 80 and over
  • Aortic Valve / pathology*
  • Aortic Valve / surgery
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / surgery*
  • Calcinosis / diagnosis
  • Calcinosis / surgery*
  • Europe / epidemiology
  • Female
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Postoperative Complications / epidemiology
  • Prospective Studies
  • Prosthesis Design
  • Registries*
  • Severity of Illness Index
  • Survival Rate / trends
  • Transcatheter Aortic Valve Replacement / methods*
  • Treatment Outcome

Supplementary concepts

  • Aortic Valve, Calcification of

Associated data

  • ClinicalTrials.gov/NCT01991431