Differentiating Renal Neoplasms From Simple Cysts on Contrast-Enhanced CT on the Basis of Attenuation and Homogeneity

AJR Am J Roentgenol. 2017 Apr;208(4):801-804. doi: 10.2214/AJR.16.17119.

Abstract

Objective: The purpose of this study is to compare the attenuation and homogeneity of renal neoplasms with those of cysts on contrast-enhanced CT.

Materials and methods: A total of 129 renal neoplasms and 24 simple cysts were evaluated. Two readers determined whether each mass was qualitatively heterogeneous or homogeneous. Mean, minimum, and maximum attenuation values were measured. Statistical analysis was performed.

Results: A total of 116 heterogeneous renal cell carcinomas (RCCs) (99 clear cell, four papillary, four oncocytic, seven chromophobe, and two unclassified RCCs), 13 homogeneous RCCs (10 papillary, two oncocytic, and one chromophobe RCC), and 24 cysts (all of which were homogeneous) were evaluated. All homogeneous RCCs had mean attenuation values of more than 42 HU, whereas renal cysts had mean attenuation values of up to 30 HU (p < 0.001). Two readers qualitatively and identically categorized all RCCs as homogeneous or heterogeneous (κ = 1.0; p < 0.001).

Conclusion: Homogeneous simple renal cysts can have mean attenuation values of up to 30 HU, as determined by contrast-enhanced CT, whereas homogeneous RCCs have mean attenuation values as low as 42 HU, with no overlap occurring between the two groups. These data suggest that further evaluation of a homogeneous renal mass with a mean attenuation value of 30 HU or less on a contrast-enhanced CT scan likely is unwarranted.

Keywords: Hounsfield units; cysts; homogeneity; kidney; renal neoplasms.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media
  • Diagnosis, Differential
  • Female
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Iohexol*
  • Kidney Diseases, Cystic / diagnostic imaging*
  • Kidney Neoplasms / diagnostic imaging*
  • Male
  • Middle Aged
  • Observer Variation
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*

Substances

  • Contrast Media
  • Iohexol