[The isolated pulmonary nodule. Biopsy guided by x-ray computed tomography]

J Radiol. 1989;70(4):249-51.
[Article in French]

Abstract

Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT).

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Needle* / adverse effects
  • Female
  • Hemoptysis / etiology
  • Humans
  • Male
  • Middle Aged
  • Pneumothorax / etiology
  • Retrospective Studies
  • Solitary Pulmonary Nodule / diagnostic imaging
  • Solitary Pulmonary Nodule / pathology*
  • Tomography, X-Ray Computed*