Impact of Diabetes Mellitus on Intravascular Ultrasound-Guided Provisional Stenting in Coronary Bifurcation Lesions J-REVERSE Sub-Study

J Interv Cardiol. 2016 Dec;29(6):576-587. doi: 10.1111/joic.12353. Epub 2016 Nov 14.

Abstract

Objective: To investigate the impact of diabetes mellitus (DM) on provisional coronary bifurcation stenting under the complete guidance of intravascular-ultrasound (IVUS).

Background: The efficacy of such intervention has not yet been fully elucidated in the DM patients.

Methods: A total of 100 DM and 139 non-DM patients in a prospective multi-center registry of IVUS-guided bifurcation stenting were compared in angiographic results at 9 months. Vessel and luminal changes during the intervention were analyzed using the IVUS. Vascular healing at the follow-up was also investigated in 23 lesions in each group using optical coherence tomography (OCT).

Results: No difference was detected regarding baseline reference vessel diameter and minimum lumen diameter in proximal main vessel (MV), distal MV, and side branch (SB). The rate of everolimus-eluting stent use (78.4% vs. 78.3%), final kissing inflation (60.1% vs. 49.0%), and conversion to 2-stent strategy (2.9% vs. 2.8%) were also similar. In the DM group, late loss was greater in proximal MV (DM 0.23 ± 0.29 vs. non-DM 0.16 ± 0.24 mm, P < 0.05) and SB (0.04 ± 0.49 vs. -0.08 ± 0.35 mm, P < 0.05). Smaller vessel area restricted stent expansion in the proximal MV (6.18 ± 1.67 vs. 6.72 ± 2.07 mm2 , P < 0.05). More inhomogeneous neointimal coverage (unevenness score, 1.90 ± 0.33 vs. 1.72 ± 0.29, P < 0.05) and more frequent thrombus attachment (26% vs. 4%, P < 0.05) were documented in the proximal MV at 9-month follow-up OCT.

Conclusions: Despite IVUS optimization for coronary bifurcation, DM is potentially associated with smaller luminal gain, higher late-loss, and inhomogeneous vascular healing with frequent thrombus attachment in the proximal MV.

MeSH terms

  • Aged
  • Angioplasty, Balloon, Coronary* / adverse effects
  • Angioplasty, Balloon, Coronary* / instrumentation
  • Angioplasty, Balloon, Coronary* / methods
  • Comorbidity
  • Coronary Angiography / methods
  • Coronary Artery Disease* / diagnosis
  • Coronary Artery Disease* / epidemiology
  • Coronary Artery Disease* / surgery
  • Coronary Vessels* / diagnostic imaging
  • Coronary Vessels* / pathology
  • Diabetes Mellitus / epidemiology*
  • Drug-Eluting Stents / adverse effects*
  • Everolimus / therapeutic use
  • Female
  • Humans
  • Japan / epidemiology
  • Male
  • Middle Aged
  • Outcome and Process Assessment, Health Care
  • Postoperative Complications* / diagnosis
  • Postoperative Complications* / epidemiology
  • Prospective Studies
  • Reproducibility of Results
  • Risk Factors
  • Tomography, Optical Coherence / methods*
  • Ultrasonography, Interventional / methods*

Substances

  • Everolimus