Purpose: We aimed to determine the clinical effectiveness of combined stent insertion and high-intensity focused ultrasound (HIFU) ablation for patients with malignant obstructive jaundice (MOJ).
Materials and methods: From June 2013 to May 2015, consecutive patients with inoperable MOJ underwent biliary stent with or without HIFU ablation in our center. Treatment-related complications, stent patency time, and survival time were compared between 2 groups.
Results: During the enrolled time, a total of 51 patients with MOJ underwent biliary stent with HIFU ablation (n=24) or biliary stent only (n=27) in our center. There was no significant difference in baseline data between 2 groups. Relief of jaundice was achieved in all patients in both groups. Cholangitis was observed in 2 patients in stent with HIFU ablation group and 1 patient in stent only group (P=0.483). Reobstruction of stent was observed in 4 patients in stent with HIFU ablation group and 8 patients in stent only group (P=0.276). The mean stent patency time was 367±41 days in stent with HIFU ablation group and 257±35 days in stent only group (P=0.037). The mean overall survival was 238±31 days in stent with HIFU ablation group and 152±20 days in stent only group (P=0.014).
Conclusions: Combined biliary stent insertion and HIFU ablation is a safe and easy method for patients with MOJ, and seems to extend stent patency time and survival when compared with biliary stent only.