CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

Eur Radiol. 2017 May;27(5):1963-1970. doi: 10.1007/s00330-016-4547-4. Epub 2016 Aug 25.

Abstract

Objectives: To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD).

Methods: Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time × weight [kg] × 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard.

Results: The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV).

Conclusions: CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD.

Key points: • TAVI-planning CT using variable helical pitch (VHP) scanning is useful. • The average volume of contrast material was 38.7 ± 8.5 mL. • The average attenuations of all the arteries were >400 HU. • This CT had a high sensitivity and NPV for excluding obstructive CAD.

Keywords: Contrast media; Coronary artery disease; Multidetector computed tomography; Sensitivity and specificity; Transcatheter aortic valve replacement.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aorta / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis / surgery*
  • Computed Tomography Angiography
  • Contrast Media
  • Coronary Angiography / methods
  • Coronary Artery Disease / diagnostic imaging*
  • Coronary Stenosis / diagnostic imaging*
  • Electrocardiography
  • Female
  • Femoral Artery / diagnostic imaging
  • Humans
  • Iliac Artery / diagnostic imaging
  • Male
  • Preoperative Care
  • Retrospective Studies
  • Tomography, Spiral Computed / methods
  • Tomography, X-Ray Computed / methods
  • Transcatheter Aortic Valve Replacement / methods

Substances

  • Contrast Media