Background: Rural-dwelling hemodialysis patients have less frequent contact with nephrologists than urban-dwelling patients, and are known to have higher mortality. We hypothesized that rural-dwelling hemodialysis patients would have more evidence of poorly controlled extracellular fluid volume (ECVF) than otherwise similar urban-dwellers.
Methods: We studied prevalent hemodialysis patients within a single renal program in Alberta, Canada and assessed ECFV using bioimpedance spectroscopy (BIS). Our primary outcome was impedance vector length (ohm/m) as assessed by BIS using the Xitron Hydra 4200 device, where shorter vector length indicated poorer ECFV control. Because poor ECFV control can lead to hypertension, we also assessed pre- and post-dialysis blood pressure. We measured outcomes at baseline.
Results: We studied 228 hemodialysis patients, of whom 115 (50.4 %) and 113 (49.6 %) were urban- and rural-dwelling, respectively. There were no differences in volume control in urban versus rural participants; odds ratio (OR) for vector length in the lowest sex-specific quartile of vector length was 0.93 (95 % CI 0.54, 1.59) after adjusting for age, sex, diabetic status, years since dialysis initiation and phase angle. The odds of very poor blood pressure control (pre-dialysis blood pressure ≥180/100) did not differ between urban and rural participants [fully adjusted OR 0.96 (0.36, 2.60)].
Conclusions: Differences in ECFV control do not appear to explain higher mortality among remote- and rural- dwelling hemodialysis patients, compared to urban-dwellers.
Keywords: Bioimpedance; Extracellular fluid volume control; Hemodialysis; Rural-dwelling; Vector length.