Background: Point-of-care ultrasound is an emerging technology in critical care medicine. Despite requirements for critical care medicine fellowship programs to demonstrate knowledge and competency in point-of-care ultrasound, tools to guide competency-based training are lacking.
Objective: We describe the development and validity arguments of a competency assessment tool for critical care ultrasound.
Methods: A modified Delphi method was used to develop behaviorally anchored checklists for 2 ultrasound applications: "Perform deep venous thrombosis study (DVT)" and "Qualify left ventricular function using parasternal long axis and parasternal short axis views (Echo)." One live rater and 1 video rater evaluated performance of 28 fellows. A second video rater evaluated a subset of 10 fellows. Validity evidence for content, response process, and internal consistency was assessed.
Results: An expert panel finalized checklists after 2 rounds of a modified Delphi method. The DVT checklist consisted of 13 items, including 1.00 global rating step (GRS). The Echo checklist consisted of 14 items, and included 1.00 GRS for each of 2 views. Interrater reliability evaluated with a Cohen kappa between the live and video rater was 1.00 for the DVT GRS, 0.44 for the PSLA GRS, and 0.58 for the PSSA GRS. Cronbach α was 0.85 for DVT and 0.92 for Echo.
Conclusions: The findings offer preliminary evidence for the validity of competency assessment tools for 2 applications of critical care ultrasound and data on live versus video raters.